<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE article
  PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.0 20120330//EN" "http://jats.nlm.nih.gov/publishing/1.0/JATS-journalpublishing1.dtd">
<article article-type="research-article" dtd-version="1.0" specific-use="sps-1.8" xml:lang="es" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">
	<front>
		<journal-meta>
			<journal-id journal-id-type="publisher-id">reh</journal-id>
			<journal-title-group>
				<journal-title>Revista Estomatológica Herediana</journal-title>
				<abbrev-journal-title abbrev-type="publisher">Rev. Estomatol. Herediana</abbrev-journal-title>
			</journal-title-group>
			<issn pub-type="ppub">1019-4355</issn>
			<issn pub-type="epub">2225-7616</issn>
			<publisher>
				<publisher-name>Universidad Peruana Cayetano Heredia. Facultad de Estomatología</publisher-name>
			</publisher>
		</journal-meta>
		<article-meta>
			<article-id pub-id-type="doi">10.20453/reh.v34i1.5297</article-id>
			<article-id pub-id-type="publisher-id">00002</article-id>
			<article-categories>
				<subj-group subj-group-type="heading">
					<subject>Artículo original</subject>
				</subj-group>
			</article-categories>
			<title-group>
				<article-title>Comparación de la microdureza de resina compuesta con técnica índex convencional y modificada con cubeta impresa en dos tiempos de fotopolimerizado</article-title>
				<trans-title-group xml:lang="en">
					<trans-title>Comparison of the microhardness of composite resin with conventional and modified index techniques with printed cuvette in two light-curing times</trans-title>
				</trans-title-group>
				<trans-title-group xml:lang="pt">
					<trans-title>Comparação da microdureza da resina composta com a técnica de índice convencional e modificada com moldeira impressa em dois tempos de fotopolimerização</trans-title>
				</trans-title-group>
			</title-group>
			<contrib-group>
				<contrib contrib-type="author">
					<contrib-id contrib-id-type="orcid">0000-0003-0550-4817</contrib-id>
					<name>
						<surname>Santos-Busso</surname>
						<given-names>Alfonso Napoleón</given-names>
					</name>
					<xref ref-type="aff" rid="aff1b"><sup>1</sup></xref>
					<role>Cirujano dentista</role>
				</contrib>
				<contrib contrib-type="author">
					<contrib-id contrib-id-type="orcid">0000-0002-9723-4166</contrib-id>
					<name>
						<surname>Larios-Quijada</surname>
						<given-names>Lucia Elena</given-names>
					</name>
					<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
					<role>Cirujano dentista</role>
				</contrib>
				<contrib contrib-type="author">
					<contrib-id contrib-id-type="orcid">0000-0002-1867-3145</contrib-id>
					<name>
						<surname>Hernández-Espino</surname>
						<given-names>Raúl</given-names>
					</name>
					<xref ref-type="aff" rid="aff3"><sup>3</sup></xref>
					<role>Cirujano dentista, Maestro en Estomatología</role>
				</contrib>
				<contrib contrib-type="author">
					<contrib-id contrib-id-type="orcid">0000-0001-5220-3588</contrib-id>
					<name>
						<surname>Huertas Mogollon</surname>
						<given-names>Gustavo Augusto</given-names>
					</name>
					<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
					<role>Cirujano dentista</role>
				</contrib>
			</contrib-group>
			<aff id="aff1">
				<label>1</label>
				<institution content-type="original">Universidad Científica del Sur, Facultad de Ciencias de la Salud. Lima, Perú.</institution>
				<institution content-type="normalized">Universidad Científica del Sur</institution>
				<institution content-type="orgname">Universidad Científica del Sur</institution>
				<institution content-type="orgdiv1">Facultad de Ciencias de la Salud</institution>
				<addr-line>
					<named-content content-type="city">Lima</named-content>
				</addr-line>
				<country country="PE">Peru</country>
			</aff>
			<aff id="aff2">
				<label>2 </label>
				<institution content-type="original">Universidad del Valle de México, Facultad de Ciencias de la Salud. Sonora, México.</institution>
				<institution content-type="normalized">Universidad del Valle de Mexico</institution>
				<institution content-type="orgname">Universidad del Valle de México</institution>
				<institution content-type="orgdiv1">Facultad de Ciencias de la Salud</institution>
				<addr-line>
					<named-content content-type="city">Sonora</named-content>
				</addr-line>
				<country country="MX">Mexico</country>
			</aff>
			<aff id="aff3">
				<label>3</label>
				<institution content-type="original">Universidad Autónoma de Ica, Ica, Perú</institution>
				<institution content-type="normalized">Universidad Autónoma de Ica</institution>
				<addr-line>
					<named-content content-type="city">Ica</named-content>
				</addr-line>
				<country country="PE">Perú</country>
			</aff>
			<aff id="aff1b">
				<label>1</label>
				<institution content-type="original">Universidad Científica del Sur, Facultad de Ciencias de la Salud. Lima, Perú.</institution>
				<institution content-type="normalized">Universidad Científica del Sur</institution>
				<institution content-type="orgname">Universidad Científica del Sur</institution>
				<institution content-type="orgdiv1">Facultad de Ciencias de la Salud</institution>
				<addr-line>
					<named-content content-type="city">Lima</named-content>
				</addr-line>
				<country country="PE">Peru</country>
				<email>alfonso.santos.busso@hotmail.com</email>
			</aff>
			<author-notes>
				<corresp id="c1"> 					Correspondencia:  Alfonso Napoleón Santos Busso Unidad vecinal Victor Manuel Maurtua D-200, Ica, Ica, Perú Código postal: 11011 Correo electrónico: <email>alfonso.santos.busso@hotmail.com</email>
				</corresp>
				<fn fn-type="conflict" id="fn1">
					<p>Conflicto de intereses:
					 Los autores declaran no tener conflicto de interés. </p>
				</fn>
				<fn fn-type="other" id="fn2">
					<p>Contribuciones de los autores: 
					Todos los autores contribuyeron con la elaboración de este manuscrito.</p>
				</fn>
			</author-notes>
			<!--<pub-date publication-format="electronic" date-type="pub">
			<day>31</day>
			<month>03</month>
			<year>2024</year>
			</pub-date>
			<pub-date publication-format="electronic" date-type="collection">
				<season></season>
				<year></year>
			</pub-date>-->
			<pub-date pub-type="epub-ppub">
				<season>Jan-Mar</season>
				<year>2024</year>
			</pub-date>
			<volume>34</volume>
			<issue>1</issue>
			<fpage>7</fpage>
			<lpage>16</lpage>
			<history>
				<date date-type="received">
					<day>01</day>
					<month>03</month>
					<year>2023</year>
				</date>
				<date date-type="accepted">
					<day>24</day>
					<month>11</month>
					<year>2023</year>
				</date>
			</history>
			<permissions>
				<license license-type="open-access" xlink:href="https://creativecommons.org/licenses/by/4.0/" xml:lang="es">
					<license-p>Este es un artículo publicado en acceso abierto bajo una licencia Creative Commons</license-p>
				</license>
			</permissions>
			<abstract>
				<title>RESUMEN</title>
				<sec>
					<title>Objetivo:</title>
					<p> Comparar la microdureza de la resina compuesta con técnica índex convencional y modificada con cubeta impresa en dos fotopolimerizaciones. </p>
				</sec>
				<sec>
					<title>Materiales y métodos:</title>
					<p> Se contó con seis grupos de estudio de acuerdo a la técnica y a la cantidad de fotopolimerizaciones: técnica directa con una fotopolimerización (D1F), directa con dos fotopolimerizaciones (D2F), índex convencional con una fotopolimerización (IC1F), índex convencional con dos fotopolimerizaciones (IC2F), índex modificada con una fotopolimerización (IM1F), índex modificada con dos fotopolimerizaciones (IM2F). Se utilizaron quince muestras por cada grupo. Las muestras tuvieron dimensiones de 2 mm de altura por 5 mm de diámetro. Se realizó la fotopolimerización siguiendo las indicaciones del grupo al que corresponde, para luego someter a la prueba de dureza de Vickers a tres indentaciones por cada cara con carga de 200 g por 15 segundos. Se realizaron dos registros de microdureza, una superficial y otra a 2 mm. Se recolectaron los datos en el instrumento confeccionado y fueron procesados mediante SPSS v. 26. </p>
				</sec>
				<sec>
					<title>Resultados:</title>
					<p> Existe una diferencia significativa entre los grupos de microdureza superficial de primera fotopolimerización (p &lt; 0,001); y también existe diferencia significativa entre los grupos de microdureza a 2 mm de primera fotopolimerización (p &lt; 0,001). Asimismo, no existen diferencias significativas entre los grupos de microdureza superficial de segunda fotopolimerización (p = 0,519) ni en los grupos de microdureza a 2 mm de segunda fotopolimerización (p = 0,279). Conclusiones: No existen diferencias significativas en la microdureza superficial y a 2 mm de profundidad con técnica índex convencional y modificada en cubeta impresa en dos fotopolimerizaciones.</p>
				</sec>
			</abstract>
			<trans-abstract xml:lang="en">
				<title>ABSTRACT</title>
				<sec>
					<title>Objective:</title>
					<p> To compare the microhardness of composite resin with conventional and modified index techniques with a printed tray in two light cures. </p>
				</sec>
				<sec>
					<title>Materials and methods:</title>
					<p> There were six study groups according to the technique and the number of photopolymerizations: direct technique with one photopolymerization (D1F), direct with two photopolymerizations (D2F), conventional index with one photopolymerization (IC1F), conventional index with two photopolymerizations (IC2F), modified index with one photopolymerization (IM1F), modified index with two photopolymerizations (IM2F). Fifteen samples were used for each group. The samples had dimensions of 2 mm in height by 5 mm in diameter. The photopolymerization was performed following the indications of the group to which it corresponds and then subjected to the Vickers hardness test with three indentations on each side with a load of 200 g for 15 seconds. Two microhardness recordings were made, one superficial and the other at 2 mm. </p>
				</sec>
				<sec>
					<title>Results:</title>
					<p> There is a significant difference between the first light-curing surface microhardness groups (p &lt; 0.001), and there is also a significant difference between the first light-curing 2 mm microhardness groups (p &lt; 0.001). Likewise, there are no significant differences between the second light-curing surface microhardness groups (p = 0.519) or the second light-curing 2 mm microhardness groups (p = 0.279). </p>
				</sec>
				<sec>
					<title>Conclusions:</title>
					<p> There are no significant differences in surface microhardness and microhardness at 2 mm depth with conventional and modified index techniques in printed trays in two photopolymerizations.</p>
				</sec>
			</trans-abstract>
			<trans-abstract xml:lang="pt">
				<title>RESUMO</title>
				<sec>
					<title>Objetivo:</title>
					<p> Comparar a microdureza da resina composta com a técnica de índice convencional e modificada com moldeira impressa em duas fotopolimerizações. </p>
				</sec>
				<sec>
					<title>Materiais e métodos:</title>
					<p> Foram constituídos seis grupos de estudo de acordo com a técnica e o número de ciclos de fotopolimerização: técnica direta com um ciclo de fotopolimerização (D1F), direta com dois ciclos de fotopolimerização (D2F), índice convencional com um ciclo de fotopolimerização (IC1F), índice convencional com dois ciclos de fotopolimerização (IC2F), índice modificado com um ciclo de fotopolimerização (IM1F), índice modificado com dois ciclos de fotopolimerização (IM2F). Foram utilizadas quinze amostras para cada grupo. Os espécimes tinham 2 mm de altura por 5 mm de diâmetro. A fotopolimerização foi efetuada de acordo com as indicações do grupo a que corresponde, e depois submetida ao teste de dureza Vickers com três indentações de cada lado com uma carga de 200 g durante 15 segundos. Foram efetuados dois registos de microdureza, um superficial e outro a 2 mm. Os dados foram recolhidos no instrumento e processados utilizando o SPSS v. 26. </p>
				</sec>
				<sec>
					<title>Resultados:</title>
					<p> Há uma diferença significativa entre os primeiros grupos de microdureza superficial fotopolimerizável (p &lt; 0,001); e há também uma diferença significativa entre os primeiros grupos de microdureza de 2 mm fotopolimerizável (p &lt; 0,001). Da mesma forma, não há diferença significativa entre os grupos de microdureza da superfície do segundo fotopolimerizador (p = 0,519) e nos grupos de microdureza de 2 mm do segundo fotopolimerizador (p = 0,279). </p>
				</sec>
				<sec>
					<title>Conclusões:</title>
					<p> Não existem diferenças significativas na microdureza da superfície e na microdureza a 2 mm de profundidade com a técnica de índice convencional e modificada em duas fotopolimerizações.</p>
				</sec>
			</trans-abstract>
			<kwd-group xml:lang="es">
				<title>Palabras clave:</title>
				<kwd>Dureza</kwd>
				<kwd>resinas compuestas</kwd>
				<kwd>técnica in vitro</kwd>
				<kwd>odontología</kwd>
			</kwd-group>
			<kwd-group xml:lang="en">
				<title>Keywords:</title>
				<kwd>Hardness</kwd>
				<kwd>composite resins</kwd>
				<kwd>in vitro technique</kwd>
				<kwd>dentistry</kwd>
			</kwd-group>
			<kwd-group xml:lang="pt">
				<title>Palavras-chave:</title>
				<kwd>Dureza</kwd>
				<kwd>resinas compostas</kwd>
				<kwd>técnica in vitro</kwd>
				<kwd>medicina dentária</kwd>
			</kwd-group>
			<counts>
				<fig-count count="3"/>
				<table-count count="2"/>
				<equation-count count="0"/>
				<ref-count count="34"/>
				<page-count count="10"/>
			</counts>
		</article-meta>
	</front>
	<body>
		<sec sec-type="intro">
			<title>INTRODUCCIÓN</title>
			<p>La técnica de resina estampada e inyectada es usada para la realización de restauraciones provisionales y definitivas <xref ref-type="bibr" rid="B1"><sup>1</sup></xref>. Diversos artículos refieren sobre la técnica índex para distintos tratamientos mediante el uso de plantillas impresas como parte de la planificación con diseño digital, encontrando resultados óptimos y satisfactorios al aplicar estas restauraciones en pacientes; de este modo, se realiza lo que conocemos como flujo digital en odontología, el cual permite reducir el tiempo de trabajo y tener una mayor precisión en los tratamientos realizados. La técnica índex consiste en colocar la resina en la superficie dental y, con ayuda de una matriz de silicona transparente, realizar la restauración directamente en la pieza dentaria <xref ref-type="bibr" rid="B2"><sup>2</sup></xref><sup>-</sup><xref ref-type="bibr" rid="B7"><sup>7</sup></xref>. En diversos artículos se ha encontrado la modificación del grosor de la matriz de silicona de la técnica índex <xref ref-type="bibr" rid="B8"><sup>8</sup></xref><sup>-</sup><xref ref-type="bibr" rid="B13"><sup>13</sup></xref>, esto debido a la penetración de la luz que provoca la fotopolimerización de la resina.</p>
			<p>El avance tecnológico en la odontología ha llevado a que las técnicas de restauración cambien a lo largo del tiempo, ello en búsqueda siempre de la realización de un tratamiento óptimo para lograr el éxito. Estos avances tecnológicos conllevan el uso de la odontología digital y la asistencia de un software de diseño, que se complementa, en algunos casos, con impresoras; además, el uso de las nuevas técnicas de restauración dependerá también de la experiencia y la capacitación del profesional <xref ref-type="bibr" rid="B14"><sup>14</sup></xref><sup>-</sup><xref ref-type="bibr" rid="B19"><sup>19</sup></xref>.</p>
			<p>Los tratamientos con las nuevas tecnologías requieren de la capacitación del odontólogo. Distintos artículos dan a conocer los protocolos de restauración; sin embargo, todos mencionan que se deben respetar las indicaciones dadas por los fabricantes de los materiales que se utilizarán. Cabe mencionar que cada artículo propone una variación en la técnica con matriz de silicona transparente convencional, también llamada índex, siendo la principal variación la que se aplica al tamaño de la matriz de silicona, dado que la distancia entre la lámpara de fotopolimerizado y la resina es un factor que influye en la fotopolimerización de la misma; sin embargo, esto se podría ver compensado por un mayor tiempo de fotopolimerizado <xref ref-type="bibr" rid="B2"><sup>2</sup></xref><sup>-</sup><xref ref-type="bibr" rid="B7"><sup>7</sup></xref>.</p>
			<p>Los avances tecnológicos se ven reflejados en las resinas, dado que actualmente tienen mejores propiedades físicas y químicas. Las resinas microhíbridas ayudan a soportar grandes tensiones debido a las partículas de tamaño y composición diferentes <xref ref-type="bibr" rid="B13"><sup>13</sup></xref><sup>-</sup><xref ref-type="bibr" rid="B15"><sup>15</sup></xref>, y permiten que se tenga un mejor manejo de la estética al momento de realizar la restauración, sin que se pierdan sus propiedades mecánicas. Los ensayos de microdureza son los más utilizados para medir las propiedades mecánicas de distintos materiales, ya que pueden detectar la capacidad de un cuerpo a resistir ser rayado (o también definido como la resistencia de este a ser indentado) <xref ref-type="bibr" rid="B19"><sup>19</sup></xref>. En diversos estudios sobre la microdureza de las resinas compuestas polimerizadas, se hace referencia a que en la cara superior de la resina se encontró mayor microdureza que en la cara inferior, variando según la distancia a la que se coloque la unidad emisora de luz que le permitirá fotopolimerizar <xref ref-type="bibr" rid="B19"><sup>19</sup></xref><sup>-</sup><xref ref-type="bibr" rid="B25"><sup>25</sup></xref>. Al ser así, las resinas son resistentes a las cargas y a la abrasión, y aumenta sus valores mientras más próxima se encuentre la fuente emisora de luz a la resina, siendo esto positivo <xref ref-type="bibr" rid="B25"><sup>25</sup></xref><sup>-</sup><xref ref-type="bibr" rid="B32"><sup>32</sup></xref>.</p>
			<p>El presente estudio tuvo como objetivo determinar si existen diferencias significativas en la microdureza de la resina compuesta con técnica índex convencional y modificada con cubeta impresa en una y dos fotopolimerizaciones.</p>
		</sec>
		<sec sec-type="materials|methods">
			<title>MATERIAL Y MÉTODOS</title>
			<p>La metodología utilizada en la presente investigación fue relacional, con un enfoque cuantitativo, experimental, transversal y prospectivo.</p>
			<p>Para la realización del estudio se trabajaron los siguientes grupos:</p>
			<p>Técnica directa con una fotopolimerización (D1F)</p>
			<p>Técnica directa con dos fotopolimerizaciones (D2F)</p>
			<p>Técnica índex convencional con una fotopolimerización (IC1F)</p>
			<p>Técnica índex convencional con dos fotopolimerizaciones (IC2F)</p>
			<p>Técnica índex modificada con una fotopolimerización (IM1F)</p>
			<p>Técnica índex modificada con dos fotopolimerizaciones (IM2F)</p>
			<p>El tamaño de la muestra se determinó por la fórmula de comparación de medias a un nivel de confianza de 95 %, con un poder estadístico de 0,8 y la varianza de la prueba piloto, obteniéndose así seis muestras por grupo; sin embargo, para tener una mayor representatividad, se optó por utilizar quince muestras por cada grupo, generando un total de 90 muestras (cada una con dos registros de microdureza: superficial y a 2 mm). Para la elaboración de los discos de resina se emplearon arandelas de cobre con 2 mm de altura por 5 mm de diámetro (19) (<xref ref-type="fig" rid="f1">figura 1</xref>), en las cuales se colocó la resina para formar los discos con las mismas dimensiones que las arandelas de cobre y luego fueron fotopolimerizados de acuerdo con el grupo de experimentación (<xref ref-type="fig" rid="f2">figuras 2</xref> y <xref ref-type="fig" rid="f3">3</xref>). </p>
			<p>
				<fig id="f1">
					<label>Figura 1</label>
					<caption>
						<title>Esquema de fotopolimerización de los grupos D1F y D2F. A: lámparade fotopolimerización; B: cinta celuloide; C: resina compuesta; D: arandela de cobre; E: platina de vidrio.</title>
					</caption>
        <graphic xlink:href="1019-4355-reh-34-01-7-gf1.jpg"/>
				</fig>
			</p>
			<p>
				<fig id="f2">
					<label>Figura 2</label>
					<caption>
						<title>Esquema de fotopolimerización de los grupos IC1F y IC2F.A: lámpara de fotopolimerización; B: matriz de silicona de 10 mm; C: cinta celuloide; D: resina compuesta; E: arandela de cobre; F: platina de vidrio.</title>
					</caption>
					<graphic xlink:href="1019-4355-reh-34-01-7-gf2.jpg"/>
				</fig>
			</p>
			<p>
				<fig id="f3">
					<label>Figura 3</label>
					<caption>
						<title>Esquema de fotopolimerización de los grupos IM1F y IM2F. A: lámpara de fotopolimerización; B: matriz de silicona y cubeta impresa de 4 mm; C: cinta celuloide; D: resina compuesta; E: arandela de cobre; F: platina de vidrio.</title>
					</caption>
					<graphic xlink:href="1019-4355-reh-34-01-7-gf3.jpg"/>
				</fig>
			</p>
			<p>Los discos seleccionados para la investigación fueron los que cumplían con las medidas antes indicadas y se excluyeron aquellos que estaban rayados, con burbujas o mal fotopolimerizados. Los discos de resina se trabajaron de la siguiente manera:</p>
			<p>Para el grupo D1F:</p>
			<p>Con una espátula modeladora mh mini (LM Dark Diamond, Finlandia) se colocó la resina compuesta tono A1 (Reflectys, Itena) <xref ref-type="bibr" rid="B24"><sup>24</sup></xref> dentro de las arandelas de cobre (2 mm de altura por 5 mm de diámetro) <xref ref-type="bibr" rid="B19"><sup>19</sup></xref>. Para la obtención de una superficie lisa, en la parte inferior se colocó la arandela en una platina de vidrio de 10 cm × 10 cm, y en la parte superior se colocó una cinta celuloide que se quedó durante el polimerizado y que fue retirada antes de la toma de registro de microdureza. La resina fue fotopolimerizada de forma individual con una lámpara Elipar™ DeepCure (3M<sup>TM</sup>, Minnesota, EE. UU.) con los parámetros de 1470 mW/cm<sup>2</sup> durante 20 segundos al ras de la resina compuesta. Luego de 24 horas, todas las muestras del grupo de primera fotopolimerización fueron sometidas a la prueba de dureza de Vickers (25) con una media de 3 indentaciones con una carga de 200 g por 15 segundos para cada una, tomando registro de microdureza superficial y a 2 mm de la resina compuesta fotopolimerizada. Se registraron ambas caras del disco fotopolimerizado.</p>
			<p>Para el grupo D2F:</p>
			<p>Con una espátula modeladora mh mini (LM Dark Diamond, Finlandia) se colocó la resina compuesta tono A1 (Reflectys, Itena) <xref ref-type="bibr" rid="B24"><sup>24</sup></xref> dentro de las arandelas de cobre (2 mm de altura por 5 mm de diámetro) <xref ref-type="bibr" rid="B19"><sup>19</sup></xref>. Para la obtención de una superficie lisa, en la parte inferior se colocó la arandela en una platina de vidrio de 10 cm × 10 cm y en la parte superior se colocó una cinta celuloide que se quedó durante el polimerizado y que fue retirada antes de la toma de registro de microdureza. La resina fue fotopolimerizada de forma individual con una lámpara Elipar™ DeepCure (3M<sup>TM</sup>, Minnesota, EE. UU.) con los parámetros de 1470 mW/cm<sup>2</sup> durante 20 segundos al ras de la resina compuesta; además, en un período no mayor a 1 minuto, se realizó la segunda fotopolimerización, simulando el tiempo que nos toma para eliminar excesos o dar retoques. La segunda fotopolimerización se realizó por el mismo lado donde se dio el disparo de luz directo al disco de resina, pero antes se aplicó glicerina para eliminar la capa inhibida por el oxígeno. Luego de 24 horas, todas las muestras del grupo de primera fotopolimerización fueron sometidas a la prueba de dureza de Vickers <xref ref-type="bibr" rid="B25"><sup>25</sup></xref> con una media de 3 indentaciones con una carga de 200 g por 15 segundos para cada una, tomando registro de microdureza superficial y a 2 mm de la resina compuesta fotopolimerizada. Se registraron ambas caras del disco fotopolimerizado.</p>
			<p>Para el grupo IC1F:</p>
			<p>Con una espátula modeladora mh mini (LM Dark Diamond, Finlandia) se colocó la resina compuesta tono A1 (Reflectys, Itena) <xref ref-type="bibr" rid="B24"><sup>24</sup></xref> dentro de las arandelas de cobre (2 mm de altura por 5 mm de diámetro) <xref ref-type="bibr" rid="B19"><sup>19</sup></xref>. Para la obtención de una superficie lisa, en la parte inferior se colocó la arandela en una platina de vidrio de 10 cm × 10 cm y en la parte superior se colocó una cinta celuloide que fue retirada antes del fotopolimerizado, y sobre esta resina se puso una matriz de silicona por adición transparente (Exaclear<sup>TM</sup>, GM) de un espesor de 10 mm, la cual fue confeccionada con la ayuda de un bloque vacío de resina de 2 mm de espesor en sus paredes (Creality, China), que fue diseñado digitalmente mediante los programas Thinkercad (Autodesk, Mill Valley, California, EE. UU.) y Meshmixer v. 3.5 (Autodesk, Mill Valley, California, EE. UU.) y elaborado con la impresora 3D Shuffle XL (Phrozen, Taiwan). Luego de obtener la matriz, se le dio un baño de poliuretano en espray y con la jeringa triple de la unidad dental se le aplicó aire a 40 PSI durante 20 segundos hasta ver que el poliuretano no deje ondas por su estado aún líquido, y luego se reservó por una hora. Posteriormente, la resina fue fotopolimerizada de forma individual con una lámpara Elipar™ DeepCure (3M<sup>TM</sup>, Minnesota, EE. UU.) con los parámetros de 1470 mW/cm<sup>2</sup> durante 20 segundos al ras de la resina compuesta. Después de 24 horas, todas las muestras del grupo de primera fotopolimerización fueron sometidas a la prueba de dureza de Vickers <xref ref-type="bibr" rid="B25"><sup>25</sup></xref> con una media de 3 indentaciones con una carga de 200 g por 15 segundos para cada una, tomando registro de microdureza superficial y a 2 mm de la resina compuesta fotopolimerizada. Se registraron ambas caras del disco fotopolimerizado.</p>
			<p>Para el grupo IC2F:</p>
			<p>Con una espátula modeladora mh mini (LM Dark Diamond, Finlandia) se colocó la resina compuesta tono A1 (Reflectys, Itena) <xref ref-type="bibr" rid="B24"><sup>24</sup></xref> dentro de las arandelas de cobre (2 mm de altura por 5 mm de diámetro) <xref ref-type="bibr" rid="B19"><sup>19</sup></xref>. Para la obtención de una superficie lisa, en la parte inferior se colocó la arandela en una platina de vidrio de 10 cm × 10 cm y en la parte superior se colocó una cinta celuloide que fue retirada antes del fotopolimerizado, y sobre esta resina se puso una matriz de silicona por adición transparente (Exaclear<sup>TM</sup>, GM) de un espesor de 10 mm, la cual fue confeccionada con la ayuda de un bloque vacío de resina de 2 mm de espesor en sus paredes (Creality, China), que fue diseñado digitalmente mediante los programas Thinkercad (Autodesk, Mill Valley, California, EE. UU.) y Meshmixer v. 3.5 (Autodesk, Mill Valley, California, EE. UU.) y elaborado con la impresora 3D Shuffle XL (Phrozen, Taiwan). Luego de obtener la matriz, se le dio un baño de poliuretano en espray y con la jeringa triple de la unidad dental se le aplicó aire a 40 PSI durante 20 segundos hasta ver que el poliuretano no deje ondas por su estado aún líquido, y luego se reservó por una hora. Posteriormente, la resina fue fotopolimerizada de forma individual con una lámpara Elipar™ DeepCure (3M<sup>TM</sup>, Minnesota, EE. UU.) con los parámetros de 1470 mW/cm<sup>2</sup> durante 20 segundos al ras de la resina compuesta; además, en un período no mayor a 1 minuto, se realizó la segunda fotopolimerización, simulando el tiempo que nos toma para eliminar excesos o dar retoques. Esta segunda fotopolimerización se realizó por el mismo lado donde se dio el disparo de luz directo al disco de resina, pero antes se aplicó glicerina para eliminar la capa inhibida por el oxígeno. Después de 24 horas, todas las muestras del grupo de primera fotopolimerización fueron sometidas a la prueba de dureza de Vickers <xref ref-type="bibr" rid="B25"><sup>25</sup></xref> con una media de 3 indentaciones con una carga de 200 g por 15 segundos para cada una, tomando registro de microdureza superficial y a 2 mm de la resina compuesta fotopolimerizada. Se registraron ambas caras del disco fotopolimerizado.</p>
			<p>Para el grupo I2F:</p>
			<p>Con una espátula modeladora mh mini (LM Dark Diamond, Finlandia) se colocó la resina compuesta tono A1 (Reflectys, Itena) <xref ref-type="bibr" rid="B24"><sup>24</sup></xref> dentro de las arandelas de cobre (2 mm de altura por 5 mm de diámetro) <xref ref-type="bibr" rid="B19"><sup>19</sup></xref>. Para la obtención de una superficie lisa, en la parte inferior se colocó la arandela en una platina de vidrio de 10 cm × 10 cm y en la parte superior se colocó una cinta celuloide que fue retirada antes del fotopolimerizado. Sobre esta resina se puso una matriz de silicona por adición transparente, de un espesor de 2 mm, la cual fue confeccionada con la ayuda de un bloque, simulando la cubeta de resina de 2 mm de grosor; con un baño de poliuretano en espray y con la jeringa triple de la unidad dental se aplicó aire a 40 PSI durante 20 segundos hasta ver que el poliuretano no deje ondas por su estado aún líquido; y se reservó por una hora para luego ser utilizada aplicándole la silicona transparente y evitar que esta no se polimerice por la capa inhibida por oxígeno propia de la resina impresa. La cubeta fue diseñada digitalmente mediante los programas Thinkercad y Meshmixer v. 3.5 y elaborada con la impresora 3D Shuffle XL, dando un total de grosor de 4 mm juntas (2 mm de cubeta de resina y 2 mm de silicona transparente). Bajo esta matriz creada junto con el molde impreso, se procedió a fotopolimerizar la resina de forma individual con una lámpara Elipar™ DeepCure (3M<sup>TM</sup>, Minnesota, EE. UU.) con los parámetros de 1470 mW/cm<sup>2</sup> durante 20 segundos al ras de la resina compuesta. Cabe decir que mientras se realizó la fotopolimerización de un disco, los demás discos de resina fueron cubiertos con papel film negro, quedando expuesto solo el disco a fotopolimerizar. Luego de 24 horas, todas las muestras del grupo de primera fotopolimerización fueron sometidas a la prueba de dureza de Vickers (25) con una media de 3 indentaciones con una carga de 200 g por 15 segundos para cada una, tomando registro de microdureza superficial y a 2 mm de la resina compuesta fotopolimerizada. Se registraron ambas caras del disco fotopolimerizado.</p>
			<p>Para el grupo IM2F:</p>
			<p>Con una espátula modeladora mh mini (LM Dark Diamond, Finlandia) se colocó la resina compuesta tono A1 (Reflectys, Itena) <xref ref-type="bibr" rid="B24"><sup>24</sup></xref> dentro de las arandelas de cobre (2 mm de altura por 5 mm de diámetro) <xref ref-type="bibr" rid="B19"><sup>19</sup></xref>. Para la obtención de una superficie lisa, en la parte inferior se colocó la arandela en una platina de vidrio de 10 cm × 10 cm y en la parte superior se colocó una cinta celuloide que fue retirada antes del fotopolimerizado. Sobre esta resina se puso una matriz de silicona por adición transparente de un espesor de 2 mm, la cual fue confeccionada con la ayuda de un bloque, simulando la cubeta impresa de resina de 2 mm de grosor; con un baño de poliuretano en espray y con la jeringa triple de la unidad dental se aplicó aire a 40 PSI durante 20 segundos hasta ver que el poliuretano no deje ondas por su estado aún líquido; y se reservó por una hora para luego ser utilizada aplicándole la silicona transparente y evitar que esta no se polimerice por la capa inhibida por oxígeno propia de la resina impresa. La cubeta fue diseñada digitalmente mediante los programas Thinkercad y Meshmixer v. 3.5 y elaborada con la impresora 3D Shuffle XL, dando un total de grosor de 4 mm juntas (2 mm de cubeta de resina y 2 mm de silicona transparente). Bajo esta matriz creada junto con el molde impreso, se procedió a fotopolimerizar la resina de forma individual con una lámpara Elipar™ DeepCure (3M<sup>TM</sup>, Minnesota, EE. UU.) con los parámetros de 1470 mW/cm<sup>2</sup> durante 20 segundos al ras de la resina compuesta. Cabe decir que mientras se realizó la fotopolimerización de un disco, los demás discos de resina fueron cubiertos con papel film negro, quedando expuesto solo el disco a fotopolimerizar; además, en un período no mayor a 1 minuto, se realizó la segunda fotopolimerización, simulando el tiempo que nos toma para eliminar excesos o dar retoques. Esta segunda fotopolimerización se realizó por el mismo lado donde se dio el disparo de luz directo al disco de resina, pero antes se aplicó glicerina para eliminar la capa inhibida por el oxígeno. Luego de 24 horas, todas las muestras del grupo de primera fotopolimerización fueron sometidas a la prueba de dureza de Vickers <xref ref-type="bibr" rid="B25"><sup>25</sup></xref> con una media de 3 indentaciones con una carga de 200 g por 15 segundos para cada una, tomando registro de microdureza superficial y a 2 mm de la resina compuesta fotopolimerizada. Se registraron ambas caras del disco fotopolimerizado. </p>
			<p>Los datos fueron recolectados en el instrumento confeccionado para la investigación. Luego fueron llevados al programa Excel para ser procesados por el programa SPSS (Statistical Package for the Social Sciences) en su versión 26. Se verificó que no existe una distribución normal de los datos mediante la prueba de Kolmogorov-Smirnov. Posteriormente, se realizó el análisis inferencial para determinar la asociación de variables mediante la prueba de Kruskal-Wallis y se realizó una prueba post hoc por cada grupo de restauración. Se consideró un nivel de significancia del 5 %. </p>
			<p>Debido al nivel de la investigación y a que no se utilizaron muestras de seres humanos, no se necesitó la aprobación de un comité de ética.</p>
		</sec>
		<sec sec-type="results">
			<title>RESULTADOS</title>
			<p>Se encontró que, en los grupos de una fotopolimerización, la media y la desviación estándar (DE) de la microdureza superficial en el grupo de D1F fue de 51,18 (DE = 0,86); mientras que en el grupo IM1F fue de 45,69 (DE = 1,23); y en el grupo IC1F se encontró una media de 42,87 (DE = 2,78). Por otro lado, en los grupos de dos fotopolimerizaciones, se observó que en el grupo D2F la media de la microdureza superficial fue de 47,96 (DE = 2,53); en el grupo IM2F fue de 46,90 (DE = 2,03); y en el grupo IC2F fue de 46,97 (DE = 1,41) (<xref ref-type="table" rid="t1">tabla 1</xref>). </p>
			<p>
				<table-wrap id="t1">
					<label>Tabla 1</label>
					<caption>
						<title>Descripción de la microdureza superficial y a 2 mm de resina compuesta con técnica índex convencional y modificada con cubeta impresa en una y dos fotopolimerizaciones.</title>
					</caption>
					<graphic xlink:href="1019-4355-reh-34-01-7-gt1.jpg"/>
					<table-wrap-foot>
						<fn id="TFN1">
							<p>Hv: microdureza de Vickers</p>
						</fn>
						<fn id="TFN2">
							<p>X: promedio</p>
						</fn>
						<fn id="TFN3">
							<p>DE: desviación estándar</p>
						</fn>
					</table-wrap-foot>
				</table-wrap>
			</p>
			<p>Respecto a la microdureza a 2 mm, se encontró que al realizar una fotopolimerización la media fue de 46,30 (DE = 1,13) en el grupo D1F; en el grupo IM1F fue de 35,97 (DE = 1,41); y en el grupo IC1M se encontró una media de 32,35 (DE = 1,23). Mientras que en los grupos de dos fotopolimerizaciones se encontró que la microdureza a 2 mm tuvo una media de 40,55 (DE = 4,90) en el grupo D2F; en el grupo IM2F fue de 41,51 (DE = 1,02); y en el grupo IC2F se encontró una media de 42,38 (DE = 1,42) (tabla 1).</p>
			<p>También se observa que existe una diferencia significativa entre los grupos de microdureza superficial y a 2 mm de una fotopolimerización (p &lt; 0,001); asimismo, se encuentra que no existen diferencias significativas entre los grupos de microdureza superficial y a 2 mm de segunda fotopolimerización (p = 0,519 y p = 0,279) (<xref ref-type="table" rid="t2">tabla 2</xref>).</p>
			<p>
				<table-wrap id="t2">
					<label>Tabla 2</label>
					<caption>
						<title>Prueba post hoc para comparación por pares para la microdureza superficial y a 2 mm de resina compuesta con técnica índex convencional y modificada con cubeta impresa en una y dos fotopolimerizaciones.</title>
					</caption>
					<graphic xlink:href="1019-4355-reh-34-01-7-gt2.jpg"/>
					<table-wrap-foot>
						<fn id="TFN4">
							<p>Nota: Valor de p &lt; 0,05</p>
						</fn>
						<fn id="TFN5">
							<label><sup>*</sup></label>
							<p> Diferencia significativa</p>
						</fn>
					</table-wrap-foot>
				</table-wrap>
			</p>
		</sec>
		<sec sec-type="discussion">
			<title>DISCUSIÓN</title>
			<p>El avance tecnológico ha llevado a que la odontología también pueda favorecerse, dado que los materiales y equipos han evolucionado, de modo que se puede trabajar en la actualidad con la odontología digitalizada que facilita los tratamientos para el paciente; sin embargo, el éxito dependerá también de la experiencia y la capacitación del odontólogo <xref ref-type="bibr" rid="B1"><sup>1</sup></xref><sup>-</sup><xref ref-type="bibr" rid="B6"><sup>6</sup></xref>. Es así como surge la importancia de la presente investigación, dado que, con las últimas técnicas de restauración, al momento de realizar la fotopolimerización, la fuente de luz ya no se coloca de forma directa a la resina compuesta, sino que entre ambas se encuentra una matriz de resina que podría ser de distintos tamaños.</p>
			<p>Gómez Basurto et al. <xref ref-type="bibr" rid="B5"><sup>5</sup></xref> buscaron determinar la influencia de una bebida gaseosa en la dureza superficial de distintas resinas comerciales; utilizaron como población de estudio a 10 muestras por cada marca de resinas, contando en total con 60 muestras de 15 ± 1 mm de diámetro por 1,5 ± 0,5 mm de altura; y encontraron que una de las resinas cuenta con una media de microdureza de 82,817. En el presente estudio, se buscó determinar si existen diferencias significativas entre la microdureza superficial en tres grupos distintos de fotopolimerización y dos tiempos de fotopolimerización; para lo cual se utilizaron 15 muestras por cada grupo, teniendo un total de 90 muestras; se estandarizó cada disco para que las medidas de todos sean de 5 mm de diámetro por 2 mm de altura; y se obtuvo como resultado que existen diferencias significativas en la microdureza de los grupos de primera fotopolimerización, y no se encontraron diferencias significativas en los grupos de segunda fotopolimerización. En comparación con el estudio de Gómez Basurto et al. <xref ref-type="bibr" rid="B5"><sup>5</sup></xref>. en la presente investigación se tuvo un número mayor de muestras y todos los discos tuvieron las mismas medidas.</p>
			<p>Scoville <xref ref-type="bibr" rid="B19"><sup>19</sup></xref> en su investigación comparó la microdureza de una resina compuesta que ha sido fotopolimerizada a distintas distancias, contando con 7 grupos de 10 muestras cada uno y curado a distancias con y sin matriz de silicona; además, la prueba de microdureza que utilizó fue la prueba de Knoop, realizada en 4 puntos distintos de la superficie. Este autor encontró que el lado superior presentó mayor microdureza que el lado inferior; y la media mayor que obtuvo fue de 44,0 KHN; además, concluyó que luego de realizar la primera fotopolimerización con matriz de silicona es necesaria realizar una segunda fotopolimerización. En el presente estudio, se ha utilizado una muestra mayor a la del estudio antes mencionado (15 por grupo en lugar de 10); además, la prueba de microdureza que se utilizó fue la prueba de Vickers, dado que la de Knoop no es posible realizar en el país; de igual manera, se optó por la prueba de Vickers porque es la más indicada para muestras pequeñas y redondeadas; y la misma se realizó en 3 puntos distintos de cada superficie. Al igual que el estudio antes mencionado, se encontró que existe una mayor microdureza en el lado superior que en el inferior y, tomando como referencia el mismo estudio, se utilizó una segunda fotopolimerización en todos los grupos y es así como se llegó a encontrar que no existen diferencias significativas. </p>
			<p>Nithya et al. <xref ref-type="bibr" rid="B21"><sup>21</sup></xref> en su estudio evaluaron el efecto del pulido de las resinas en la microdureza, utilizando un total de 450 muestras y la prueba de microdureza de Struers; los autores determinaron que con el pulido existe un nivel mayor de microdureza. En el presente estudio, no se realizó ningún tipo de pulido a los discos de resina que fueron parte de los distintos grupos de estudio y el tamaño de las muestras fue mucho menor. Así también, se encontró que, al momento de realizar la segunda fotopolimerización, desaparece esa diferencia significativa que existe en la primera fotopolimerización; además, para obtener una superficie lisa en la resina se colocó una matriz celuloide.</p>
			<p>Vásquez-Castro et al. <xref ref-type="bibr" rid="B33"><sup>33</sup></xref> buscaron determinar el tiempo necesario de fotopolimerización en una resina bulk-fill a 3 mm de espesor, midiendo así la microdureza de la superficie y la microdureza base. Los autores encontraron que se necesita un tiempo mínimo de 40 segundos para poder fotopolimerizar en la base del disco de resina de 3 mm de espesor. En la presente investigación, a diferencia de la investigación citada, se utilizaron matrices de silicona de distinto espesor para observar la microdureza de la resina a distintas distancias de la lámpara fotopolimerizadora y la resina, utilizando el mismo tiempo de 40 segundos y se encontraron resultados similares. </p>
			<p>De León et al. <xref ref-type="bibr" rid="B34"><sup>34</sup></xref> encontraron que las intensidades menores de 400 mW/cm<sup>2</sup> generan citotoxicidad en las resinas y producen que sus propiedades mecánicas disminuyan. En la presente investigación, se utilizó una lámpara con una intensidad de 1470 mW/cm<sup>2</sup>, y se encontró que se obtiene una adecuada microdureza superficial y a 2 mm; además, se halló que realizar dos fotopolimerizaciones con las distintas técnicas estudiadas ayuda a obtener los mismos resultados que una restauración directa.</p>
			<p>El presente estudio, a diferencia de los que se encuentran en la literatura, se realizó con dos medidas distintas de las matrices de resina, con el fin de proponer que dicha matriz puede llegar a medir tan solo 2 mm en lugar de los 10 mm que se indica en la técnica actualmente; asimismo, se realizó con la prueba de microdureza de Vickers debido a que es la única a la que se puede acceder en el país, y se utilizaron muestras distintas en los grupos de primera y segunda fotopolimerización.</p>
			<p>La principal limitación del estudio fue la realización en la prueba de microdureza en escala de Vickers, dado que, en la actualidad, la misma se suele realizar en la escala de Knoop; sin embargo, en el Perú solo se tiene mayor acceso al equipo para medir la microdureza en la escala de Vickers. </p>
		</sec>
		<sec sec-type="conclusions">
			<title>CONCLUSIONES</title>
			<p>No existen diferencias significativas en la microdureza superficial y a 2 mm de profundidad de la resina compuesta fotopolimerizada con técnica índex convencional y modificada en cubeta impresa en dos fotopolimerizaciones.</p>
			<p>Existen diferencias significativas en la microdureza superficial y a 2 mm de profundidad de la resina compuesta fotopolimerizada con técnica índex convencional y modificada en cubeta impresa en un fotopolimerizado.</p>
			<p>En ese sentido, el segundo fotopolimerizado es importante para la disminución de las diferencias de microdureza que puedan existir entre las técnicas de restauración.</p>
			<p>Se sugiere que se realicen estudios in vivo para reforzar los procedimientos clínicos y, de ser viable, modificar los procedimientos clínicos.</p>
		</sec>
	</body>
	<back>
		<ack>
			<title>Agradecimientos: </title>
			<p>Ninguno.</p>
		</ack>
		<ref-list>
			<title>REFERENCIAS BIBLIOGRÁFICAS</title>
			<ref id="B1">
				<label>1</label>
				<mixed-citation>Gestakovski D. The injectable composite resin technique: minimally invasive reconstruction of esthetics and function. Clinical case report with 2-year follow-up. Quintessence Int [Internet]. 2019; 50(9): 712-719. Disponible en: https://doi.org/10.3290/j.qi.a43089</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Gestakovski</surname>
							<given-names>D</given-names>
						</name>
					</person-group>
					<article-title>The injectable composite resin technique: minimally invasive reconstruction of esthetics and function. Clinical case report with 2-year follow-up</article-title>
					<source>Quintessence Int</source>
					<year>2019</year>
					<volume>50</volume>
					<issue>9</issue>
					<fpage>712</fpage>
					<lpage>719</lpage>
					<pub-id pub-id-type="doi">10.3290/j.qi.a43089</pub-id>
				</element-citation>
			</ref>
			<ref id="B2">
				<label>2</label>
				<mixed-citation>Xia J, Li Y, Cai D, Shi X, Zhao S, Jiang Q, et al. Direct resin composite restoration of maxillary central incisors using a 3D-printed template: two clinical cases. BMC Oral Health [Internet]. 2018; 18(1): 158. Disponible en: https://doi.org/10.1186/s12903-018-0621-4</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Xia</surname>
							<given-names>J</given-names>
						</name>
						<name>
							<surname>Li</surname>
							<given-names>Y</given-names>
						</name>
						<name>
							<surname>Cai</surname>
							<given-names>D</given-names>
						</name>
						<name>
							<surname>Shi</surname>
							<given-names>X</given-names>
						</name>
						<name>
							<surname>Zhao</surname>
							<given-names>S</given-names>
						</name>
						<name>
							<surname>Jiang</surname>
							<given-names>Q</given-names>
						</name>
						<etal/>
					</person-group>
					<article-title>Direct resin composite restoration of maxillary central incisors using a 3D-printed template: two clinical cases</article-title>
					<source>BMC Oral Health</source>
					<year>2018</year>
					<volume>18</volume>
					<issue>1</issue>
					<fpage>158</fpage>
					<lpage>158</lpage>
					<pub-id pub-id-type="doi">10.1186/s12903-018-0621-4</pub-id>
				</element-citation>
			</ref>
			<ref id="B3">
				<label>3</label>
				<mixed-citation>Cortés-Bretón Brinkmann J, Albanchez-González MI, Lobato Peña DM, García Gil I, Suárez García MJ, Peláez Rico J. Improvement of aesthetics in a patient with tetracycline stains using the injectable composite resin technique: case report with 24-month follow-up. Br Dent J [Internet]. 2020; 229(12): 774-778. Disponible en: https://doi.org/10.1038/s41415-020-2405-x</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Cortés-Bretón Brinkmann</surname>
							<given-names>J</given-names>
						</name>
						<name>
							<surname>Albanchez-González</surname>
							<given-names>MI</given-names>
						</name>
						<name>
							<surname>Lobato Peña</surname>
							<given-names>DM</given-names>
						</name>
						<name>
							<surname>García Gil</surname>
							<given-names>I</given-names>
						</name>
						<name>
							<surname>Suárez García</surname>
							<given-names>MJ</given-names>
						</name>
						<name>
							<surname>Peláez Rico</surname>
							<given-names>J</given-names>
						</name>
					</person-group>
					<article-title>Improvement of aesthetics in a patient with tetracycline stains using the injectable composite resin technique: case report with 24-month follow-up</article-title>
					<source>Br Dent J</source>
					<year>2020</year>
					<volume>229</volume>
					<issue>12</issue>
					<fpage>774</fpage>
					<lpage>778</lpage>
					<pub-id pub-id-type="doi">10.1038/s41415-020-2405-x</pub-id>
				</element-citation>
			</ref>
			<ref id="B4">
				<label>4</label>
				<mixed-citation>Blasi A, Alnassar T, Chiche G. Injectable technique for direct provisional restoration. J Esthet Restor Dent [Internet]. 2018; 30(2): 85-88. Disponible en: https://doi.org/10.1111/jerd.12333</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Blasi</surname>
							<given-names>A</given-names>
						</name>
						<name>
							<surname>Alnassar</surname>
							<given-names>T</given-names>
						</name>
						<name>
							<surname>Chiche</surname>
							<given-names>G</given-names>
						</name>
					</person-group>
					<article-title>Injectable technique for direct provisional restoration</article-title>
					<source>J Esthet Restor Dent</source>
					<year>2018</year>
					<volume>30</volume>
					<issue>2</issue>
					<fpage>85</fpage>
					<lpage>88</lpage>
					<pub-id pub-id-type="doi">10.1111/jerd.12333</pub-id>
				</element-citation>
			</ref>
			<ref id="B5">
				<label>5</label>
				<mixed-citation>Gómez Basurto S, Noriega Barba M, Guerrero Ibarra J, Borges Yáñez A. Evaluación in vitro de la microdureza superficial de diferentes resinas comerciales, frente a la acción de una bebida gaseosa. Rev Odont Mex [Internet]. 2010; 14(1): 8-14. Disponible en: <ext-link ext-link-type="uri" xlink:href="https://revistas.unam.mx/index.php/rom/article/view/15419/14666">https://revistas.unam.mx/index.php/rom/article/view/15419/14666</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Gómez Basurto</surname>
							<given-names>S</given-names>
						</name>
						<name>
							<surname>Noriega Barba</surname>
							<given-names>M</given-names>
						</name>
						<name>
							<surname>Guerrero Ibarra</surname>
							<given-names>J</given-names>
						</name>
						<name>
							<surname>Borges Yáñez</surname>
							<given-names>A</given-names>
						</name>
					</person-group>
					<article-title>Evaluación in vitro de la microdureza superficial de diferentes resinas comerciales, frente a la acción de una bebida gaseosa</article-title>
					<source>Rev Odont Mex</source>
					<year>2010</year>
					<volume>14</volume>
					<issue>1</issue>
					<fpage>8</fpage>
					<lpage>14</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://revistas.unam.mx/index.php/rom/article/view/15419/14666">https://revistas.unam.mx/index.php/rom/article/view/15419/14666</ext-link>
				</element-citation>
			</ref>
			<ref id="B6">
				<label>6</label>
				<mixed-citation>Anusavice KJ, Phillips. Ciencia de los materiales dentales. 13.a ed. Madrid: Elsevier Imprint; 2022.</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<name>
							<surname>Anusavice</surname>
							<given-names>KJ</given-names>
						</name>
						<name>
							<surname>Phillips</surname>
							<given-names/>
						</name>
					</person-group>
					<source>Ciencia de los materiales dentales.13.a ed</source>
					<year>2022</year>
					<publisher-loc>Madrid</publisher-loc>
					<publisher-name>Elsevier Imprint</publisher-name>
				</element-citation>
			</ref>
			<ref id="B7">
				<label>7</label>
				<mixed-citation>Sampaio CS, Puppin-Rontani J, Tonolli G, Atria PJ. Workflow of digitally guided direct composite resin restorations using open source software and 3D printing: a clinical technique. Quintessence Int [Internet]. 2021; 52(2): 104-110. Disponible en: https://doi.org/10.3290/j.qi.a45426</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Sampaio</surname>
							<given-names>CS</given-names>
						</name>
						<name>
							<surname>Puppin-Rontani</surname>
							<given-names>J</given-names>
						</name>
						<name>
							<surname>Tonolli</surname>
							<given-names>G</given-names>
						</name>
						<name>
							<surname>Atria</surname>
							<given-names>PJ</given-names>
						</name>
					</person-group>
					<article-title>Workflow of digitally guided direct composite resin restorations using open source software and 3D printing: a clinical technique</article-title>
					<source>Quintessence Int</source>
					<year>2021</year>
					<volume>52</volume>
					<issue>2</issue>
					<fpage>104</fpage>
					<lpage>110</lpage>
					<pub-id pub-id-type="doi">10.3290/j.qi.a45426</pub-id>
				</element-citation>
			</ref>
			<ref id="B8">
				<label>8</label>
				<mixed-citation>Ammannato R, Rondoni D, Ferraris F. Update on the index technique in worn dentition: a no-prep restorative approach with a digital workflow. Int J Esthet Dent [Internet]. 2018; 13(4): 516-537. Disponible en: <ext-link ext-link-type="uri" xlink:href="https://pubmed.ncbi.nlm.nih.gov/30302440/">https://pubmed.ncbi.nlm.nih.gov/30302440/</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Ammannato</surname>
							<given-names>R</given-names>
						</name>
						<name>
							<surname>Rondoni</surname>
							<given-names>D</given-names>
						</name>
						<name>
							<surname>Ferraris</surname>
							<given-names>F</given-names>
						</name>
					</person-group>
					<article-title>Update on the index technique in worn dentition: a no-prep restorative approach with a digital workflow</article-title>
					<source>Int J Esthet Dent</source>
					<year>2018</year>
					<volume>13</volume>
					<issue>4</issue>
					<fpage>516</fpage>
					<lpage>537</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://pubmed.ncbi.nlm.nih.gov/30302440/">https://pubmed.ncbi.nlm.nih.gov/30302440/</ext-link>
				</element-citation>
			</ref>
			<ref id="B9">
				<label>9</label>
				<mixed-citation>Cervino G, Fiorillo L, Arzukanyan AV, Spagnuolo G, Cicciù M. Dental restorative digital workflow: digital smile design from aesthetic to function. Dent J (Basel) [Internet]. 2019; 7(2): 30. Disponible en: https://doi.org/10.3390/dj7020030</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Cervino</surname>
							<given-names>G</given-names>
						</name>
						<name>
							<surname>Fiorillo</surname>
							<given-names>L</given-names>
						</name>
						<name>
							<surname>Arzukanyan</surname>
							<given-names>AV</given-names>
						</name>
						<name>
							<surname>Spagnuolo</surname>
							<given-names>G</given-names>
						</name>
						<name>
							<surname>Cicciù</surname>
							<given-names>M</given-names>
						</name>
					</person-group>
					<article-title>Dental restorative digital workflow: digital smile design from aesthetic to function</article-title>
					<source>Dent J (Basel)</source>
					<year>2019</year>
					<volume>7</volume>
					<issue>2</issue>
					<fpage>30</fpage>
					<lpage>30</lpage>
					<pub-id pub-id-type="doi">10.3390/dj7020030</pub-id>
				</element-citation>
			</ref>
			<ref id="B10">
				<label>10</label>
				<mixed-citation>Coachman C, De Arbeloa L, Mahn G, Sulaiman TA, Mahn E. An improved direct injection technique with flowable composites. A digital workflow case report. Oper Dent [Internet]. 2020; 45(3): 235-242. Disponible en: https://doi.org/10.2341/18-151-t</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Coachman</surname>
							<given-names>C</given-names>
						</name>
						<name>
							<surname>De Arbeloa</surname>
							<given-names>L</given-names>
						</name>
						<name>
							<surname>Mahn</surname>
							<given-names>G</given-names>
						</name>
						<name>
							<surname>Sulaiman</surname>
							<given-names>TA</given-names>
						</name>
						<name>
							<surname>Mahn</surname>
							<given-names>E</given-names>
						</name>
					</person-group>
					<article-title>An improved direct injection technique with flowable composites. A digital workflow case report</article-title>
					<source>Oper Dent</source>
					<year>2020</year>
					<volume>45</volume>
					<issue>3</issue>
					<fpage>235</fpage>
					<lpage>242</lpage>
					<pub-id pub-id-type="doi">10.2341/18-151-t</pub-id>
				</element-citation>
			</ref>
			<ref id="B11">
				<label>11</label>
				<mixed-citation>Salem MN, Hafez S. Aesthetic management of erosive tooth wear in a young Egyptian swimmer: a case report. Clin Cosmet Investig Dent [Internet]. 2021; 13: 201-209. Disponible en: https://doi.org/10.2147/ccide.s308045</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Salem</surname>
							<given-names>MN</given-names>
						</name>
						<name>
							<surname>Hafez</surname>
							<given-names>S</given-names>
						</name>
					</person-group>
					<article-title>Aesthetic management of erosive tooth wear in a young Egyptian swimmer: a case report</article-title>
					<source>Clin Cosmet Investig Dent</source>
					<year>2021</year>
					<volume>13</volume>
					<fpage>201</fpage>
					<lpage>209</lpage>
					<pub-id pub-id-type="doi">10.2147/ccide.s308045</pub-id>
				</element-citation>
			</ref>
			<ref id="B12">
				<label>12</label>
				<mixed-citation>Ypei Gia NR, Sampaio CS, Higashi C, Sakamoto A, Hirata R. The injectable resin composite restorative technique: a case report. J Esthet Restor Dent [Internet]. 2021; 33(3): 404-414. Disponible en: https://doi.org/10.1111/jerd.12650</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Ypei Gia</surname>
							<given-names>NR</given-names>
						</name>
						<name>
							<surname>Sampaio</surname>
							<given-names>CS</given-names>
						</name>
						<name>
							<surname>Higashi</surname>
							<given-names>C</given-names>
						</name>
						<name>
							<surname>Sakamoto</surname>
							<given-names>A</given-names>
						</name>
						<name>
							<surname>Hirata</surname>
							<given-names>R</given-names>
						</name>
					</person-group>
					<article-title>The injectable resin composite restorative technique: a case report</article-title>
					<source>J Esthet Restor Dent</source>
					<year>2021</year>
					<volume>33</volume>
					<issue>3</issue>
					<fpage>404</fpage>
					<lpage>414</lpage>
					<pub-id pub-id-type="doi">10.1111/jerd.12650</pub-id>
				</element-citation>
			</ref>
			<ref id="B13">
				<label>13</label>
				<mixed-citation>Revilla-León M, Jordan D, Methani MM, Piedra-Cascón W, Özcan M, Zandinejad A. Influence of printing angulation on the surface roughness of additive manufactured clear silicone indices: an in vitro study. J Prosthet Dent [Internet]. 2021; 125(3): 462-468. Disponible en: https://doi.org/10.1016/j.prosdent.2020.02.008</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Revilla-León</surname>
							<given-names>M</given-names>
						</name>
						<name>
							<surname>Jordan</surname>
							<given-names>D</given-names>
						</name>
						<name>
							<surname>Methani</surname>
							<given-names>MM</given-names>
						</name>
						<name>
							<surname>Piedra-Cascón</surname>
							<given-names>W</given-names>
						</name>
						<name>
							<surname>Özcan</surname>
							<given-names>M</given-names>
						</name>
						<name>
							<surname>Zandinejad</surname>
							<given-names>A</given-names>
						</name>
					</person-group>
					<article-title>Influence of printing angulation on the surface roughness of additive manufactured clear silicone indices: an in vitro study</article-title>
					<source>J Prosthet Dent</source>
					<year>2021</year>
					<volume>125</volume>
					<issue>3</issue>
					<fpage>462</fpage>
					<lpage>468</lpage>
					<pub-id pub-id-type="doi">10.1016/j.prosdent.2020.02.008</pub-id>
				</element-citation>
			</ref>
			<ref id="B14">
				<label>14</label>
				<mixed-citation>Revilla-León M, Fountain J, Piedra Cascón W, Ozcan M, Zandinejad A. Workflow description of additively manufactured clear silicone indexes for injected provisional restorations: a novel technique. J Esthet Restor Dent [Internet]. 2019; 31(3): 213-221. Disponible en: https://doi.org/10.1111/jerd.12464</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Revilla-León</surname>
							<given-names>M</given-names>
						</name>
						<name>
							<surname>Fountain</surname>
							<given-names>J</given-names>
						</name>
						<name>
							<surname>Piedra Cascón</surname>
							<given-names>W</given-names>
						</name>
						<name>
							<surname>Ozcan</surname>
							<given-names>M</given-names>
						</name>
						<name>
							<surname>Zandinejad</surname>
							<given-names>A</given-names>
						</name>
					</person-group>
					<article-title>Workflow description of additively manufactured clear silicone indexes for injected provisional restorations: a novel technique</article-title>
					<source>J Esthet Restor Dent</source>
					<year>2019</year>
					<volume>31</volume>
					<issue>3</issue>
					<fpage>213</fpage>
					<lpage>221</lpage>
					<pub-id pub-id-type="doi">10.1111/jerd.12464</pub-id>
				</element-citation>
			</ref>
			<ref id="B15">
				<label>15</label>
				<mixed-citation>Revilla-León M, Besné-Torre A, Sánchez-Rubio JL, Fábrega JJ, Özcan M. Digital tools and 3D printing technologies integrated into the workflow of restorative treatment: a clinical report. J Prosthet Dent [Internet]. 2019; 121(1): 3-8. Disponible en: https://doi.org/10.1016/j.prosdent.2018.02.020</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Revilla-León</surname>
							<given-names>M</given-names>
						</name>
						<name>
							<surname>Besné-Torre</surname>
							<given-names>A</given-names>
						</name>
						<name>
							<surname>Sánchez-Rubio</surname>
							<given-names>JL</given-names>
						</name>
						<name>
							<surname>Fábrega</surname>
							<given-names>JJ</given-names>
						</name>
						<name>
							<surname>Özcan</surname>
							<given-names>M</given-names>
						</name>
					</person-group>
					<article-title>Digital tools and 3D printing technologies integrated into the workflow of restorative treatment: a clinical report</article-title>
					<source>J Prosthet Dent</source>
					<year>2019</year>
					<volume>121</volume>
					<issue>1</issue>
					<fpage>3</fpage>
					<lpage>8</lpage>
					<pub-id pub-id-type="doi">10.1016/j.prosdent.2018.02.020</pub-id>
				</element-citation>
			</ref>
			<ref id="B16">
				<label>16</label>
				<mixed-citation>Revilla-León M, Fountain J, Piedra-Cascón W, Zandinejad A, Ozcan M. Silicone additive manufactured indices performed from a virtual diagnostic waxing for direct composite diastema closure combined with resin infiltration technique on white spot lesions: a case report. J Prosthodont [Internet]. 2019; 28(8): 855-860. Disponible en: https://doi.org/10.1111/jopr.13109</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Revilla-León</surname>
							<given-names>M</given-names>
						</name>
						<name>
							<surname>Fountain</surname>
							<given-names>J</given-names>
						</name>
						<name>
							<surname>Piedra-Cascón</surname>
							<given-names>W</given-names>
						</name>
						<name>
							<surname>Zandinejad</surname>
							<given-names>A</given-names>
						</name>
						<name>
							<surname>Ozcan</surname>
							<given-names>M</given-names>
						</name>
					</person-group>
					<article-title>Silicone additive manufactured indices performed from a virtual diagnostic waxing for direct composite diastema closure combined with resin infiltration technique on white spot lesions: a case report</article-title>
					<source>J Prosthodont</source>
					<year>2019</year>
					<volume>28</volume>
					<issue>8</issue>
					<fpage>855</fpage>
					<lpage>860</lpage>
					<pub-id pub-id-type="doi">10.1111/jopr.13109</pub-id>
				</element-citation>
			</ref>
			<ref id="B17">
				<label>17</label>
				<mixed-citation>Revilla-León M, Raney L, Piedra-Cascón W, Barrington J, Zandinejad A, Özcan M. Digital workflow for an esthetic rehabilitation using a facial and intraoral scanner and an additive manufactured silicone index: a dental technique. J Prosthet Dent [Internet]. 2020; 123(4): 564-570. Disponible en: https://doi.org/10.1016/j.prosdent.2019.03.014</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Revilla-León</surname>
							<given-names>M</given-names>
						</name>
						<name>
							<surname>Raney</surname>
							<given-names>L</given-names>
						</name>
						<name>
							<surname>Piedra-Cascón</surname>
							<given-names>W</given-names>
						</name>
						<name>
							<surname>Barrington</surname>
							<given-names>J</given-names>
						</name>
						<name>
							<surname>Zandinejad</surname>
							<given-names>A</given-names>
						</name>
						<name>
							<surname>Özcan</surname>
							<given-names>M</given-names>
						</name>
					</person-group>
					<article-title>Digital workflow for an esthetic rehabilitation using a facial and intraoral scanner and an additive manufactured silicone index: a dental technique</article-title>
					<source>J Prosthet Dent</source>
					<year>2020</year>
					<volume>123</volume>
					<issue>4</issue>
					<fpage>564</fpage>
					<lpage>570</lpage>
					<pub-id pub-id-type="doi">10.1016/j.prosdent.2019.03.014</pub-id>
				</element-citation>
			</ref>
			<ref id="B18">
				<label>18</label>
				<mixed-citation>Park SH, Piedra-Cascón W, Zandinejad A, Revilla-León M. Digitally created 3-piece additive manufactured index for direct esthetic treatment. J Prosthodont [Internet]. 2020; 29(5): 436-442. Disponible en: https://doi.org/10.1111/jopr.13159</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Park</surname>
							<given-names>SH</given-names>
						</name>
						<name>
							<surname>Piedra-Cascón</surname>
							<given-names>W</given-names>
						</name>
						<name>
							<surname>Zandinejad</surname>
							<given-names>A</given-names>
						</name>
						<name>
							<surname>Revilla-León</surname>
							<given-names>M</given-names>
						</name>
					</person-group>
					<article-title>Digitally created 3-piece additive manufactured index for direct esthetic treatment</article-title>
					<source>J Prosthodont</source>
					<year>2020</year>
					<volume>29</volume>
					<issue>5</issue>
					<fpage>436</fpage>
					<lpage>442</lpage>
					<pub-id pub-id-type="doi">10.1111/jopr.13159</pub-id>
				</element-citation>
			</ref>
			<ref id="B19">
				<label>19</label>
				<mixed-citation>Scoville DK. Curing composite resin through a clear polyvinyl siloxane matrix and its effect on microhardness [Tesis de maestría en Internet]. Houston: University of the Health Sciences; 2019. Disponible en: https://apps.dtic.mil/sti/citations/AD1128095</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<name>
							<surname>Scoville</surname>
							<given-names>DK</given-names>
						</name>
					</person-group>
					<source>Curing composite resin through a clear polyvinyl siloxane matrix and its effect on microhardness</source>
					<year>2019</year>
					<publisher-loc>Houston</publisher-loc>
					<publisher-name>University of the Health Sciences</publisher-name>
				</element-citation>
			</ref>
			<ref id="B20">
				<label>20</label>
				<mixed-citation>Palanuwech M, Limlawan T. The effect of clear silicone barrier and polymerizing depth on hardness of light-polymerized composite resin. J Dent Assoc Thai [Internet]. 2014; 64(4): 223-233. Disponible en: <ext-link ext-link-type="uri" xlink:href="https://www.jdat.org/dentaljournal/journal/view/2014OR3012">https://www.jdat.org/dentaljournal/journal/view/2014OR3012</ext-link>
				</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Palanuwech</surname>
							<given-names>M</given-names>
						</name>
						<name>
							<surname>Limlawan</surname>
							<given-names>T</given-names>
						</name>
					</person-group>
					<article-title>The effect of clear silicone barrier and polymerizing depth on hardness of light-polymerized composite resin</article-title>
					<source>J Dent Assoc Thai</source>
					<year>2014</year>
					<volume>64</volume>
					<issue>4</issue>
					<fpage>223</fpage>
					<lpage>233</lpage>
					<ext-link ext-link-type="uri" xlink:href="https://www.jdat.org/dentaljournal/journal/view/2014OR3012">https://www.jdat.org/dentaljournal/journal/view/2014OR3012</ext-link>
				</element-citation>
			</ref>
			<ref id="B21">
				<label>21</label>
				<mixed-citation>Nithya K, Sridevi K, Keerthi V, Ravishankar P. Evaluation of surface roughness, hardness, and gloss of composites after three different finishing and polishing techniques: an in vitro study. Cureus [Internet]. 2020; 12(2): e7037. Disponible en: https://doi.org/10.7759/cureus.7037</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Nithya</surname>
							<given-names>K</given-names>
						</name>
						<name>
							<surname>Sridevi</surname>
							<given-names>K</given-names>
						</name>
						<name>
							<surname>Keerthi</surname>
							<given-names>V</given-names>
						</name>
						<name>
							<surname>Ravishankar</surname>
							<given-names>P</given-names>
						</name>
					</person-group>
					<article-title>Evaluation of surface roughness, hardness, and gloss of composites after three different finishing and polishing techniques: an in vitro study</article-title>
					<source>Cureus</source>
					<year>2020</year>
					<volume>12</volume>
					<issue>2</issue>
					<elocation-id>e7037</elocation-id>
					<pub-id pub-id-type="doi">10.7759/cureus.7037</pub-id>
				</element-citation>
			</ref>
			<ref id="B22">
				<label>22</label>
				<mixed-citation>Alharbi N, Osman RB, Wismeijer D. Factors influencing the dimensional accuracy of 3D-printed full-coverage dental restorations using stereolithography technology. Int J Prosthodont [Internet]. 2016; 29(5): 503-510. Disponible en: https://doi.org/10.11607/ijp.4835</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Alharbi</surname>
							<given-names>N</given-names>
						</name>
						<name>
							<surname>Osman</surname>
							<given-names>RB</given-names>
						</name>
						<name>
							<surname>Wismeijer</surname>
							<given-names>D</given-names>
						</name>
					</person-group>
					<article-title>Factors influencing the dimensional accuracy of 3D-printed full-coverage dental restorations using stereolithography technology</article-title>
					<source>Int J Prosthodont</source>
					<year>2016</year>
					<volume>29</volume>
					<issue>5</issue>
					<fpage>503</fpage>
					<lpage>510</lpage>
					<pub-id pub-id-type="doi">10.11607/ijp.4835</pub-id>
				</element-citation>
			</ref>
			<ref id="B23">
				<label>23</label>
				<mixed-citation>Ciccone-Nogueira JC, Borsatto MC, De Souza-Zaron WC, Pereira Ramos R, Palma-Dibb RG. Microhardness of composite resins at different depths varying the post-irradiation time. J Appl Oral Sci [Internet]. 2007; 15(4): 305-309. Disponible en: https://doi.org/10.1590/s1678-77572007000400012</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Ciccone-Nogueira</surname>
							<given-names>JC</given-names>
						</name>
						<name>
							<surname>Borsatto</surname>
							<given-names>MC</given-names>
						</name>
						<name>
							<surname>De Souza-Zaron</surname>
							<given-names>WC</given-names>
						</name>
						<name>
							<surname>Pereira Ramos</surname>
							<given-names>R</given-names>
						</name>
						<name>
							<surname>Palma-Dibb</surname>
							<given-names>RG</given-names>
						</name>
					</person-group>
					<article-title>Microhardness of composite resins at different depths varying the post-irradiation time</article-title>
					<source>J Appl Oral Sci</source>
					<year>2007</year>
					<volume>15</volume>
					<issue>4</issue>
					<fpage>305</fpage>
					<lpage>309</lpage>
					<pub-id pub-id-type="doi">10.1590/s1678-77572007000400012</pub-id>
				</element-citation>
			</ref>
			<ref id="B24">
				<label>24</label>
				<mixed-citation>Itena Clinical Products. Reflectys Universal Restorative Composite. White Paper. Instructions for use. Villepinte: Itena Clinical: 2018.</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<collab>Itena Clinical Products</collab>
					</person-group>
					<source>Reflectys Universal Restorative Composite. White Paper. Instructions for use</source>
					<publisher-loc>Villepinte</publisher-loc>
					<publisher-name>Itena Clinical</publisher-name>
					<year>2018</year>
				</element-citation>
			</ref>
			<ref id="B25">
				<label>25</label>
				<mixed-citation>Warkentin M, Freyse C, Specht O, Behrend D, Maletz R, Janda R, et al. Correlation of ultrasound microscopy and Vickers hardness measurements of human dentin and enamel - A pilot study. Dent Mater [Internet]. 2018; 34(7): 1036-1040. Disponible en: https://doi.org/10.1016/j.dental.2018.03.020</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Warkentin</surname>
							<given-names>M</given-names>
						</name>
						<name>
							<surname>Freyse</surname>
							<given-names>C</given-names>
						</name>
						<name>
							<surname>Specht</surname>
							<given-names>O</given-names>
						</name>
						<name>
							<surname>Behrend</surname>
							<given-names>D</given-names>
						</name>
						<name>
							<surname>Maletz</surname>
							<given-names>R</given-names>
						</name>
						<name>
							<surname>Janda</surname>
							<given-names>R</given-names>
						</name>
						<etal/>
					</person-group>
					<article-title>Correlation of ultrasound microscopy and Vickers hardness measurements of human dentin and enamel - A pilot study</article-title>
					<source>Dent Mater</source>
					<year>2018</year>
					<volume>34</volume>
					<issue>7</issue>
					<fpage>1036</fpage>
					<lpage>1040</lpage>
					<pub-id pub-id-type="doi">10.1016/j.dental.2018.03.020</pub-id>
				</element-citation>
			</ref>
			<ref id="B26">
				<label>26</label>
				<mixed-citation>Hashemikamangar SS, Meymand MZ, Kharazifard MJ, Valizadeh S. Surface microhardness of a self-adhesive composite in comparison with conventional composite resins. Dent Med Probl [Internet]. 2020; 57(3): 247-253. Disponible en: https://doi.org/10.17219/dmp/118123</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Hashemikamangar</surname>
							<given-names>SS</given-names>
						</name>
						<name>
							<surname>Meymand</surname>
							<given-names>MZ</given-names>
						</name>
						<name>
							<surname>Kharazifard</surname>
							<given-names>MJ</given-names>
						</name>
						<name>
							<surname>Valizadeh</surname>
							<given-names>S</given-names>
						</name>
					</person-group>
					<article-title>Surface microhardness of a self-adhesive composite in comparison with conventional composite resins</article-title>
					<source>Dent Med Probl</source>
					<year>2020</year>
					<volume>57</volume>
					<issue>3</issue>
					<fpage>247</fpage>
					<lpage>253</lpage>
					<pub-id pub-id-type="doi">10.17219/dmp/118123</pub-id>
				</element-citation>
			</ref>
			<ref id="B27">
				<label>27</label>
				<mixed-citation>Barve D, Dave P, Gulve M, Saquib S, Das G, Sibghatullah M, et al. Assessment of microhardness and color stability of micro-hybrid and nano-filled composite resins. Niger J Clin Pract [Internet]. 2021; 24(10): 1499-1505. Disponible en: https://doi.org/10.4103/njcp.njcp_632_20</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Barve</surname>
							<given-names>D</given-names>
						</name>
						<name>
							<surname>Dave</surname>
							<given-names>P</given-names>
						</name>
						<name>
							<surname>Gulve</surname>
							<given-names>M</given-names>
						</name>
						<name>
							<surname>Saquib</surname>
							<given-names>S</given-names>
						</name>
						<name>
							<surname>Das</surname>
							<given-names>G</given-names>
						</name>
						<name>
							<surname>Sibghatullah</surname>
							<given-names>M</given-names>
						</name>
						<etal/>
					</person-group>
					<article-title>Assessment of microhardness and color stability of micro-hybrid and nano-filled composite resins</article-title>
					<source>Niger J Clin Pract</source>
					<year>2021</year>
					<volume>24</volume>
					<issue>10</issue>
					<fpage>1499</fpage>
					<lpage>1505</lpage>
					<pub-id pub-id-type="doi">10.4103/njcp.njcp_632_20</pub-id>
				</element-citation>
			</ref>
			<ref id="B28">
				<label>28</label>
				<mixed-citation>Dias MF, Espíndola-Castro LF, Lins-Filho PC, Teixeira HM, Silva CHV, Guimarães RP. Influence of different thermopolymerization methods on composite resin microhardness. J Clin Exp Dent [Internet]. 2020; 12(4): e335-e341. Disponible en: https://doi.org/10.4317/jced.56772</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Dias</surname>
							<given-names>MF</given-names>
						</name>
						<name>
							<surname>Espíndola-Castro</surname>
							<given-names>LF</given-names>
						</name>
						<name>
							<surname>Lins-Filho</surname>
							<given-names>PC</given-names>
						</name>
						<name>
							<surname>Teixeira</surname>
							<given-names>HM</given-names>
						</name>
						<name>
							<surname>Silva</surname>
							<given-names>CHV</given-names>
						</name>
						<name>
							<surname>Guimarães</surname>
							<given-names>RP</given-names>
						</name>
					</person-group>
					<article-title>Influence of different thermopolymerization methods on composite resin microhardness</article-title>
					<source>J Clin Exp Dent</source>
					<year>2020</year>
					<volume>12</volume>
					<issue>4</issue>
					<fpage>e335</fpage>
					<lpage>e341</lpage>
					<pub-id pub-id-type="doi">10.4317/jced.56772</pub-id>
				</element-citation>
			</ref>
			<ref id="B29">
				<label>29</label>
				<mixed-citation>Mohammadi N, Alavi FN, Rikhtehgaran S, Chaharom MEE, Salari A, Kimyai S, et al. Effect of bleaching method and curing time on the surface microhardness of microhybrid composite resin. Maedica (Bucur) [Internet]. 2020; 15(3): 359-364. Disponible en: https://doi.org/10.26574/maedica.2020.15.3.359</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Mohammadi</surname>
							<given-names>N</given-names>
						</name>
						<name>
							<surname>Alavi</surname>
							<given-names>FN</given-names>
						</name>
						<name>
							<surname>Rikhtehgaran</surname>
							<given-names>S</given-names>
						</name>
						<name>
							<surname>Chaharom</surname>
							<given-names>MEE</given-names>
						</name>
						<name>
							<surname>Salari</surname>
							<given-names>A</given-names>
						</name>
						<name>
							<surname>Kimyai</surname>
							<given-names>S</given-names>
						</name>
						<etal/>
					</person-group>
					<article-title>Effect of bleaching method and curing time on the surface microhardness of microhybrid composite resin</article-title>
					<source>Maedica (Bucur)</source>
					<year>2020</year>
					<volume>15</volume>
					<issue>3</issue>
					<fpage>359</fpage>
					<lpage>364</lpage>
					<pub-id pub-id-type="doi">10.26574/maedica.2020.15.3.359</pub-id>
				</element-citation>
			</ref>
			<ref id="B30">
				<label>30</label>
				<mixed-citation>Kelic K, Matic S, Marovic D, Klaric E, Tarle Z. Microhardness of bulk-fill composite materials. Acta Clin Croat [Internet]. 2016; 55(4): 607-614. Disponible en: https://doi.org/10.20471/acc.2016.55.04.11</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Kelic</surname>
							<given-names>K</given-names>
						</name>
						<name>
							<surname>Matic</surname>
							<given-names>S</given-names>
						</name>
						<name>
							<surname>Marovic</surname>
							<given-names>D</given-names>
						</name>
						<name>
							<surname>Klaric</surname>
							<given-names>E</given-names>
						</name>
						<name>
							<surname>Tarle</surname>
							<given-names>Z</given-names>
						</name>
					</person-group>
					<article-title>Microhardness of bulk-fill composite materials</article-title>
					<source>Acta Clin Croat</source>
					<year>2016</year>
					<volume>55</volume>
					<issue>4</issue>
					<fpage>607</fpage>
					<lpage>614</lpage>
					<pub-id pub-id-type="doi">10.20471/acc.2016.55.04.11</pub-id>
				</element-citation>
			</ref>
			<ref id="B31">
				<label>31</label>
				<mixed-citation>Haralur SB, Alqahtani MM, Alqahtani RA, Shabab RM, Hummadi KA. Effect of dentin-disinfection chemicals on shear bond strength and microhardness of resin-infiltrated human dentin in different adhesive protocols. Medicina [Internet]. 2022; 58(9): 1244. Disponible en: https://doi.org/10.3390/medicina58091244</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Haralur</surname>
							<given-names>SB</given-names>
						</name>
						<name>
							<surname>Alqahtani</surname>
							<given-names>MM</given-names>
						</name>
						<name>
							<surname>Alqahtani</surname>
							<given-names>RA</given-names>
						</name>
						<name>
							<surname>Shabab</surname>
							<given-names>RM</given-names>
						</name>
						<name>
							<surname>Hummadi</surname>
							<given-names>KA</given-names>
						</name>
					</person-group>
					<article-title>Effect of dentin-disinfection chemicals on shear bond strength and microhardness of resin-infiltrated human dentin in different adhesive protocols</article-title>
					<source>Medicina</source>
					<year>2022</year>
					<volume>58</volume>
					<issue>9</issue>
					<fpage>1244</fpage>
					<lpage>1244</lpage>
					<pub-id pub-id-type="doi">10.3390/medicina58091244</pub-id>
				</element-citation>
			</ref>
			<ref id="B32">
				<label>32</label>
				<mixed-citation>Manzoor S, Arooj Z, Waqas MA, Irshad N, Saeed A, Malik A, et al. Surface microhardness of microhybrid and nanocomposite after storage in mouth washes. J Ayub Med Coll Abbottabad [Internet]. 2022; 34(3): 540-547. Disponible en: https://doi.org/10.55519/JAMC-03-10181</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Manzoor</surname>
							<given-names>S</given-names>
						</name>
						<name>
							<surname>Arooj</surname>
							<given-names>Z</given-names>
						</name>
						<name>
							<surname>Waqas</surname>
							<given-names>MA</given-names>
						</name>
						<name>
							<surname>Irshad</surname>
							<given-names>N</given-names>
						</name>
						<name>
							<surname>Saeed</surname>
							<given-names>A</given-names>
						</name>
						<name>
							<surname>Malik</surname>
							<given-names>A</given-names>
						</name>
						<etal/>
					</person-group>
					<article-title>Surface microhardness of microhybrid and nanocomposite after storage in mouth washes</article-title>
					<source>J Ayub Med Coll Abbottabad</source>
					<year>2022</year>
					<volume>34</volume>
					<issue>3</issue>
					<fpage>540</fpage>
					<lpage>547</lpage>
					<pub-id pub-id-type="doi">10.55519/JAMC-03-10181</pub-id>
				</element-citation>
			</ref>
			<ref id="B33">
				<label>33</label>
				<mixed-citation>Vásquez-Castro E, Portella-Atamari J, Melendez-Murillo D, Ramirez-Vilchez N, Delgado-Cotrina L. Evaluación del tiempo de exposición de una resina Bulk-Fill en preparaciones profundas. Rev Estomatol Herediana [Internet]. 2022; 32(1): 30-35. Disponible en: http://dx.doi.org/10.20453/reh.v32i1.4180</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>Vásquez-Castro</surname>
							<given-names>E</given-names>
						</name>
						<name>
							<surname>Portella-Atamari</surname>
							<given-names>J</given-names>
						</name>
						<name>
							<surname>Melendez-Murillo</surname>
							<given-names>D</given-names>
						</name>
						<name>
							<surname>Ramirez-Vilchez</surname>
							<given-names>N</given-names>
						</name>
						<name>
							<surname>Delgado-Cotrina</surname>
							<given-names>L</given-names>
						</name>
					</person-group>
					<article-title>Evaluación del tiempo de exposición de una resina Bulk-Fill en preparaciones profundas</article-title>
					<source>Rev Estomatol Herediana</source>
					<year>2022</year>
					<volume>32</volume>
					<issue>1</issue>
					<fpage>30</fpage>
					<lpage>35</lpage>
					<pub-id pub-id-type="doi">10.20453/reh.v32i1.4180</pub-id>
				</element-citation>
			</ref>
			<ref id="B34">
				<label>34</label>
				<mixed-citation>De León E, Teske AP, País B, Grazioli G. Efecto de la intensidad de las unidades de fotopolimerización sobre la biocompatibilidad y resistencia a la flexión de una resina compuesta. Odontoestomatol [Internet]. 2022; 24(40): e222. Disponible en: https://doi.org/10.22592/ode2022n40e222</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>De León</surname>
							<given-names>E</given-names>
						</name>
						<name>
							<surname>Teske</surname>
							<given-names>AP</given-names>
						</name>
						<name>
							<surname>País</surname>
							<given-names>B</given-names>
						</name>
						<name>
							<surname>Grazioli</surname>
							<given-names>G</given-names>
						</name>
					</person-group>
					<article-title>Efecto de la intensidad de las unidades de fotopolimerización sobre la biocompatibilidad y resistencia a la flexión de una resina compuesta</article-title>
					<source>Odontoestomatol</source>
					<year>2022</year>
					<volume>24</volume>
					<issue>40</issue>
					<elocation-id>e222</elocation-id>
					<pub-id pub-id-type="doi">10.22592/ode2022n40e222</pub-id>
				</element-citation>
			</ref>
		</ref-list>
		<fn-group>
			<fn fn-type="other" id="fn3">
				<p>Aprobación de ética: 
				Debido al nivel de la investigación y a que no se utilizaron muestras de seres humanos, no se necesitó la aprobación de un comité de ética.</p>
			</fn>
			<fn fn-type="supported-by" id="fn4">
				<p>Financiamiento: 
				Ninguno.</p>
			</fn>
		</fn-group>
	</back>
</article>
