<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE article
  PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.0 20120330//EN" "http://jats.nlm.nih.gov/publishing/1.0/JATS-journalpublishing1.dtd">
<article article-type="research-article" dtd-version="1.0" specific-use="sps-1.8" xml:lang="es" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">
	<front>
		<journal-meta>
			<journal-id journal-id-type="publisher-id">rtq</journal-id>
			<journal-title-group>
				<journal-title>Tecnología Química</journal-title>
				<abbrev-journal-title abbrev-type="publisher">RTQ</abbrev-journal-title>
			</journal-title-group>
			<issn pub-type="epub">2224-6185</issn>
			<issn pub-type="ppub">0041-8420</issn>
			<publisher>
				<publisher-name>Universidad de Oriente</publisher-name>
			</publisher>
		</journal-meta>
		<article-meta>
			<article-id pub-id-type="publisher-id">00011</article-id>
			<article-categories>
				<subj-group subj-group-type="heading">
					<subject>Artículo original</subject>
				</subj-group>
			</article-categories>
			<title-group>
				<article-title>Ajuste del punto de operación de micro-turbinas hidráulicas a través del método de regulación de velocidad combinada</article-title>
				<trans-title-group xml:lang="en">
					<trans-title>Adjustment of the operation point of hydraulic micro-turbines through the combined speed regulation method</trans-title>
				</trans-title-group>
			</title-group>
			<contrib-group>
				<contrib contrib-type="author">
					<name>
						<surname>Peña Pupo</surname>
						<given-names>L.</given-names>
						<prefix>MSc. </prefix>
					</name>
					<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
					<xref ref-type="corresp" rid="c1"><sup>*</sup></xref>
				</contrib>
				<contrib contrib-type="author">
					<name>
						<surname>Fariñas Wong</surname>
						<given-names>E.</given-names>
						<prefix>DrC. </prefix>
					</name>
					<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
				</contrib>
				<contrib contrib-type="author">
					<name>
						<surname>Domínguez Abreu</surname>
						<given-names>H.</given-names>
						<prefix>MSc. </prefix>
					</name>
					<xref ref-type="aff" rid="aff3"><sup>3</sup></xref>
				</contrib>
				<contrib contrib-type="author">
					<name>
						<surname>Fong Barrio</surname>
						<given-names>J.</given-names>
						<prefix>MSc. </prefix>
					</name>
					<xref ref-type="aff" rid="aff3b"><sup>3</sup></xref>
				</contrib>
			</contrib-group>
			<aff id="aff1">
				<label>1</label>
				<institution content-type="original">Empresa de Hidroenergía, Cuba. </institution>
				<institution content-type="orgname">Empresa de Hidroenergía</institution>
				<institution content-type="normalized">Empresa de Hidroenergía</institution>
				<country country="CU">Cuba</country>
			</aff>
			<aff id="aff2">
				<label>2 </label>
				<institution content-type="original">Universidad Central “Marta Abreu” de las Villas. Cuba</institution>
				<institution content-type="orgname">Universidad Central “Marta Abreu” de las Villas</institution>
				<institution content-type="normalized">Universidad Central “Marta Abreu” de las Villas</institution>
				<country country="CU">Cuba</country>
			</aff>
			<aff id="aff3">
				<label>3 </label>
				<institution content-type="original">Departamento Informática. Universidad de Oriente. Cuba. </institution>
				<institution content-type="normalized">Universidad de Oriente</institution>
				<institution content-type="orgdiv1">Departamento Informática</institution>
				<institution content-type="orgname">Universidad de Oriente</institution>
				<country country="CU">Cuba</country>
			</aff>
			<aff id="aff3b">
				<label>3 </label>
				<institution content-type="original">Departamento Informática. Universidad de Oriente. Cuba. </institution>
				<institution content-type="normalized">Universidad de Oriente</institution>
				<institution content-type="orgdiv1">Departamento Informática</institution>
				<institution content-type="orgname">Universidad de Oriente</institution>
				<country country="CU">Cuba</country>
			</aff>
			<author-notes>
				<corresp id="c1">
					<label>*</label>Autor para la correspondencia. Correo electrónico: <email>leonardo@stg.hidroe.une.cu</email>
				</corresp>
				<fn fn-type="conflict" id="fn1">
					<p><bold>Conflicto de intereses</bold> Los autores declaran que no existen conflictos de intereses</p>
				</fn>
			</author-notes>
			<pub-date pub-type="epub-ppub">
				<season>Ene-Abr</season>
				<year>2020</year>
			</pub-date>
			<volume>40</volume>
			<issue>1</issue>
			<fpage>150</fpage>
			<lpage>168</lpage>
			<history>
				<date date-type="received">
					<day>19</day>
					<month>03</month>
					<year>2019</year>
				</date>
				<date date-type="accepted">
					<day>20</day>
					<month>07</month>
					<year>2019</year>
				</date>
			</history>
			<permissions>
				<license license-type="open-access" xlink:href="https://creativecommons.org/licenses/by-nc/4.0/" xml:lang="es">
					<license-p>Este es un artículo publicado en acceso abierto bajo una licencia Creative Commons</license-p>
				</license>
			</permissions>
			<abstract>
				<title>RESUMEN</title>
				<p>En este trabajo se presenta una propuesta de seguimiento del punto de operación de las micros turbinas hidráulicas en las instalaciones hidroenergéticas que trabajan en régimen autónomo. Se pretende ajustar automáticamente el punto de operación al que impone la demanda mediante el control combinado de carga y gasto.Se presentan resultados de simulación en ambiente <italic>Matlab</italic>
 <sup>
 <italic>®</italic>
</sup> 
 <italic>/Simulink</italic> con modelos obtenidos a través de vías analíticas y comprobados con técnicas de identificación experimental. Los resultados muestran que el ajuste único del punto de operación mediante la regulación por carga a pesar de tener mejores prestaciones que la regulación del gasto y ser la más empleada en las micro-turbinas hidráulicas, no aprovecha de forma óptima el portador energético. Por último, se presentan los resultados de simulación, algunas consideraciones sobre su desempeño, limitaciones y trabajos futuros.</p>
			</abstract>
			<trans-abstract xml:lang="en">
				<title>ABSTRACT</title>
				<p> In this work a proposal of following the point of operation of hydraulic micro-turbines in autonomous operation regime is presented.It is sought to adjust the operation point automatically to which imposes the demand by means of the combined control of load and flow. Simulation results are presented in Matlab®/Simulink with models obtained through analytic and proven with methods of experimental identification. Lastly, the results of simulation are presented of combining both methods, some performance considerations, limitations and future works.</p>
			</trans-abstract>
			<kwd-group xml:lang="es">
				<title>Palabras Clave:</title>
				<kwd>Punto de operación de Micro-turbinas hidráulicas</kwd>
				<kwd>Operación de Micro hidroeléctricas autónomas</kwd>
				<kwd>Métodos de regulación de velocidad</kwd>
			</kwd-group>
			<kwd-group xml:lang="en">
				<title>Keywords:</title>
				<kwd>Micro-hydropower operation point</kwd>
				<kwd>Autonomous operation</kwd>
				<kwd>speed control methods</kwd>
			</kwd-group>
			<counts>
				<fig-count count="9"/>
				<table-count count="1"/>
				<equation-count count="16"/>
				<ref-count count="43"/>
				<page-count count="19"/>
			</counts>
		</article-meta>
	</front>
	<body>
		<sec sec-type="intro">
			<title>Introducción</title>
			<p>En la actualidad, la brecha entre la oferta y la demanda de energía eléctrica aumenta cada día. Por otro lado, el potencial energético del flujo de agua en pequeños ríos puede ser explotado por una micro planta hidroeléctrica. Las centrales hidroeléctricas se clasifican en general como a pie de presa y de pasada o también conocidas como a “filo de agua”. <xref ref-type="bibr" rid="B1"><sup>1</sup></xref> Tienen un impacto ambiental menor debido a que utiliza un flujo instantáneo de agua para impulsar las turbinas <xref ref-type="bibr" rid="B2"><sup>2</sup></xref> y puede ser ventajoso ya que no conduce a la reubicación de personas. La hidroeléctrica de pasada es un tipo de generación de energía hidroeléctrica donde se proporciona poco o ningún almacenamiento de agua<xref ref-type="bibr" rid="B3"><sup>3</sup></xref> y el reservorio de almacenamiento se conoce como estanque.<xref ref-type="bibr" rid="B4"><sup>4</sup></xref><sup>)</sup> Ver <xref ref-type="fig" rid="f1">figura 1</xref>.</p>
			<p>
				<fig id="f1">
					<label>Fig. 1</label>
					<caption>
						<title>Micro central Hidroeléctrica de pasada o “a filo de agua”. </title>
					</caption>
					<graphic xlink:href="2224-6185-rtq-40-01-150-gf1.jpg"/>
					<attrib>Fuente: (Autores, 2018)</attrib>
				</fig>
			</p>
			<p>Estas plantas desempeñan un papel vital en la electrificación rural de los países en desarrollo como una generación de energía descentralizada y, por lo general, funcionan en régimen autónomo: fuera de la red y como una fuente única de energía. <xref ref-type="bibr" rid="B5"><sup>5</sup></xref><sup>,</sup><xref ref-type="bibr" rid="B6"><sup>6</sup></xref> Cuba tiene 144 centrales hidroeléctricas en funcionamiento, el 74% (107) de las cuales se encuentran en regiones montañosas aisladas del Sistema Eléctrico Nacional (SEN), lo que permite el suministro de energía de muchas personas además de lugares sociales y económicos.<xref ref-type="bibr" rid="B7"><sup>7</sup></xref> Del total de 107 mini y micro hidroeléctricas de Cuba solo 6 disponen de algún mecanismo de regulación de la velocidad de rotación de turbina, lo que implica muy baja calidad de la energía según las normas del SEN <xref ref-type="bibr" rid="B8"><sup>8</sup></xref><sup>,</sup><xref ref-type="bibr" rid="B9"><sup>9</sup></xref> y, como consecuencia no incentiva el consumo de energía. Por otro lado, solo seis del total de centrales autónomas cubanas poseen mecanismos de regulación de frecuencia, todas mediante carga secundaria.<xref ref-type="bibr" rid="B10"><sup>10</sup></xref>
			</p>
			<p>La elección de la tecnología de la turbina está dictada por los parámetros hidráulicos y topográficos y, por lo tanto, es altamente inflexible. Las turbinas se diseñan para un valor de carga y gasto predeterminados que definen la zona de operación de ellas.<xref ref-type="bibr" rid="B11"><sup>11</sup></xref><sup>,</sup><xref ref-type="bibr" rid="B12"><sup>12</sup></xref> Cualquier variación de estos parámetros se compensa abriendo o cerrando los dispositivos de control del gasto, tales como álabes directrices, válvulas o compuertas, a fin de mantener constante, ya sea la potencia de salida a la red, o el caudal que atraviesa la turbina. <xref ref-type="bibr" rid="B13"><sup>13</sup></xref><sup>,</sup><xref ref-type="bibr" rid="B14"><sup>14</sup></xref> El funcionamiento de las turbinas hidráulicas está dado por una serie de curvas características entre las que se encuentra la de potencia <italic>versus</italic> gasto, (ver <xref ref-type="fig" rid="f2">figura 2</xref>). Nótese que el punto en que opera la turbina depende del régimen de carga y puede ser ajustado a través del flujo de agua a la entrada de la turbina como rige la expresión (1).</p>
			<p>
				<disp-formula id="e1">
					<label>(1)</label>
						<alternatives>
						<graphic xlink:href="2224-6185-rtq-40-01-150-i002.jpg"/>
					</alternatives>
					</disp-formula>
			</p>
			<p>Este trabajo aborda el ajuste automático del punto de operación de las micro-turbinas hidráulicas que operan en modo autónomo a través de la combinación de la regulación por caudal (flujo) y carga secundaria. Se presenta el modelado en funciones de transferencia y su simulación en Matlab®/Simulink. Se comparan los resultados de la simulación dinámica del método del control por carga y flujo por si solos para la regulación de la velocidad de la turbina; así como la combinación de ambos métodos como vía de ajustar el punto de operación de la turbina.</p>
			<p>
				<fig id="f2">
					<label>Fig. 2</label>
					<caption>
						<title>Curva característica de trabajo de turbinas hidráulicas. 
						</title>
					</caption>
					<graphic xlink:href="2224-6185-rtq-40-01-150-gf2.jpg"/>
					<attrib>Fuente: adaptado de HydroHillChart<xref ref-type="bibr" rid="B15"><sup>15</sup></xref></attrib>
				</fig>
			</p>
		</sec>
		<sec>
			<title>Fundamentación teórica</title>
			<p>Las micro centrales hidroeléctricas de Cuba a menudo presentan problemas de operación, las principales causas según <xref ref-type="bibr" rid="B16"><sup>16</sup></xref><sup>,</sup><xref ref-type="bibr" rid="B17"><sup>17</sup></xref> son: pobre control de la frecuencia (ver <xref ref-type="fig" rid="f3">figura 3</xref>) y la potencia, deficiente distribución de la demanda. De igual forma otros factores de diseño también implican problemas en la operación como: excesiva relación entre la longitud de la tubería y la carga hidráulica (L/H), momento de inercia (GD<sup>2</sup>/4g) inadecuado,<xref ref-type="bibr" rid="B16"><sup>16</sup></xref> entre otros factores operacionales y de diseño. Todos estos aspectos se resumen es una baja calidad de la energía y una baja eficiencia energética que causa que los hidrogrupos operen fuera de su punto de operación óptimo. En la <xref ref-type="fig" rid="f3">figura 3</xref> se muestra el comportamiento de la frecuencia eléctrica generada por una micro hidroeléctrica en un día típico. Nótese que el valor de la frecuencia eléctrica generada (proporcional a la velocidad de rotación de la turbina) oscila fuera de los límites operacionales establecidos. En el caso de sistemas de pequeña potencia aislados del SEN, a falta de una norma específica, se considera que los valores nominales de frecuencia se encuentran en el rango de +/-2% instantáneos y +/-5% en un minuto.</p>
			<p>
				<fig id="f3">
					<label>Fig. 3</label>
					<caption>
						<title>Comportamiento típico de la Frecuencia de una micro-Hidroeléctrica sin regulación. </title>
					</caption>
					<graphic xlink:href="2224-6185-rtq-40-01-150-gf3.png"/>
					<attrib>Fuente: Adaptado de (López, 2018)</attrib>
				</fig>
			</p>
			<p>El 90% de las micro hidroeléctricas de Cuba operan con turbinas Pelton,<xref ref-type="bibr" rid="B7"><sup>7</sup></xref> estas tienen capacidades de regulación de frecuencia limitadas debido a los efectos de la inercia del agua <xref ref-type="bibr" rid="B18"><sup>18</sup></xref>resultado del circuito hidráulico de carga alta y por el gran valor del tiempo de apertura de los inyectores, adoptado para evitar problemas de sobrepresión transitoria en la compuerta,<xref ref-type="bibr" rid="B19"><sup>19</sup></xref> causando que la onda de presión viaje aproximadamente a 1200m/s de velocidad.<xref ref-type="bibr" rid="B20"><sup>20</sup></xref>
			</p>
			<p>Desde el punto de vista de la operación de micro-centrales hidroeléctricas, se conocen dos formas de regular la frecuencia eléctrica generada: manipulando el flujo de agua que ingresa a la turbina y ajustando la carga del generador.<xref ref-type="bibr" rid="B4"><sup>4</sup></xref><sup>, 20)</sup> Mientras que el primer método persigue ajustar el punto de operación de la turbina regulando la cantidad de flujo de agua que ingresa a la entrada de la turbina;<xref ref-type="bibr" rid="B21"><sup>21</sup></xref> el segundo pretende que la turbina trabaje en un punto de operación fijo, generalmente a potencia máxima equilibrando las cargas de los usuarios y una carga resistiva conectada en paralelo.<xref ref-type="bibr" rid="B6"><sup>6</sup></xref><sup>,</sup><xref ref-type="bibr" rid="B22"><sup>22</sup></xref> En la <xref ref-type="fig" rid="f4">figura 4</xref> se muestran los dos métodos descritos, representados por los números 1 y 2 respectivamente.</p>
			<p>
				<fig id="f4">
					<label>Fig. 4</label>
					<caption>
						<title>Esquema de regulación combinado de micro-hidroeléctricas autónomas. 1) Regulación por flujo, 2) Regulación por carga. </title>
					</caption>
					<graphic xlink:href="2224-6185-rtq-40-01-150-gf4.jpg"/>
					<attrib>Fuente: (Autores, 2019)</attrib>
				</fig>
			</p>
			<p>Para mantener el punto de operación deseado manteniendo la velocidad nominal de la turbina, se reportan varios enfoques en la literatura especializada, algunos consideran emplear los sistemas de almacenamiento en energía mecánica a través de volantes de inercia,
				<xref ref-type="bibr" rid="B23"><sup>23</sup></xref>
				 sistemas interconectados como en,
				<xref ref-type="bibr" rid="B19"><sup>19</sup></xref>
				,
				<xref ref-type="bibr" rid="B24"><sup>24</sup></xref>
				 micro redes 
				 <xref ref-type="bibr" rid="B25"><sup>25</sup></xref>
				 ,
				 <xref ref-type="bibr" rid="B26"><sup>26</sup></xref>
				  y almacenamiento de energía eléctrica.
				  <xref ref-type="bibr" rid="B27"><sup>27</sup></xref>
				  <xref ref-type="bibr" rid="B28"><sup>28</sup></xref>
				 ,
				<xref ref-type="bibr" rid="B29"><sup>29</sup></xref> 
				Otro método, con un desarrollo relativamente reciente consiste en ajustar el punto de operación al máximo impuesto por la carga mediante el uso de generadores asíncronos conectados a las turbinas Kaplan;
				<xref ref-type="bibr" rid="B30"><sup>30</sup></xref>
				,
				<xref ref-type="bibr" rid="B31"><sup>31</sup></xref> esto implica un cambio en la concepción del control de velocidad y, por lo tanto, cambiar el grupo turbina-generador en aquellos que están operando. Desde el punto de vista económico, aún no se ha reportado sea una solución factible. La vía de los sistemas interconectados y micro redes aisladas como en
				 <xref ref-type="bibr" rid="B32"><sup>32</sup></xref>
				  está fuera del alcance de los sistemas autónomos.</p>
			<p>El control de la carga secundaria tiene un diseño más sencillo y buen desempeño frente a perturbaciones impulsivas y escalonadas; sin embargo en los diseños clásicos, la potencia nominal de la carga secundaria se elige en un 30% más alta que la potencia de carga nominal.<xref ref-type="bibr" rid="B33"><sup>33</sup></xref> En este caso, se demuestra que es rentable solo cuando se requiere agua caliente para otros usos.<xref ref-type="bibr" rid="B34"><sup>34</sup></xref><sup>,</sup><xref ref-type="bibr" rid="B35"><sup>35</sup></xref> Otro relativo inconveniente está relacionado con la presencia de armónicos causado por la conmutación del rectificador controlado, lo cual es soluble aplicando las técnicas descritas por algunos autores.<xref ref-type="bibr" rid="B36"><sup>36</sup></xref> Algunos trabajos igualan la potencia secundaria a la nominal de la planta, pero a un costo elevado.<xref ref-type="bibr" rid="B37"><sup>37</sup></xref> Otros trabajos plantean la reducción de la carga secundaria a un 50% de la potencia nominal a través del ajuste del ajuste del caudal de la turbina. <xref ref-type="bibr" rid="B37"><sup>37</sup></xref> En trabajos anteriores de los autores se realiza el control de la velocidad de una turbina mediante el ajuste de carga <xref ref-type="bibr" rid="B6"><sup>6</sup></xref><sup>,</sup><xref ref-type="bibr" rid="B38"><sup>38</sup></xref><sup>,</sup><xref ref-type="bibr" rid="B39"><sup>39</sup></xref> con un valor nominal de la carga secundaria igual al 30% del valor del generador. Se ha presentado una revisión de los últimos 20 artículos publicados en el área del control por carga,<xref ref-type="bibr" rid="B22"><sup>22</sup></xref> este plantea la necesidad de aprovechar la energía consumida en la carga secundaria de forma diferente, lo que a juicio de los autores podría ser a través de: iluminación, corrección de voltaje o en algún tipo de almacenamiento energético.</p>
			<p>Los autores de este trabajo creen que la combinación de los dos métodos es una forma intuitiva de aprovechar más eficientemente el portador energético y garantizar la requerida calidad de la energía. En esta forma de operación, subyace un necesario ajuste del punto de operación de la turbina tal que se pueda ajustar a las fluctuaciones de la demanda, suministrando la energía en los estándares de calidad establecidos y aprovechando más eficientemente el portador energético.</p>
		</sec>
		<sec sec-type="methods">
			<title>Métodos utilizados y condiciones experimentales</title>
			<p>A través de una amplia revisión bibliográfica se detallan en este artículo los antecedentes de la regulación de velocidad por carga y por flujo, así como su posible combinación para mejorar el seguimiento del punto de operación de micro turbinas hidráulicas, de igual forma se caracteriza el contexto actual de la temática en Cuba y algunos requerimientos técnicos. Mediante un estudio de caso, correspondiente a la micro-central hidroeléctrica “El Dian”, del municipio Guamá, provincia Santiago de Cuba,se realiza una evaluación del comportamiento dinámico de la planta y se diseñan los algoritmos de control para los lazos de control de carga y flujo. Se evalúa el desempeño de la combinación de ambos métodos.</p>
			<p>Fue simulado mediante Matlab®/Simulink el modelo en funciones de transferencia de una micro-central hidroeléctrica de 100 kW. A través del método de asignación de polos, con los modelos analíticos generales desarrollados por algunos autores <sup>(20)</sup> fueron diseñados los lazos de control de carga y flujo descritos en la <xref ref-type="fig" rid="f4">figura 4</xref>. Estos modelos además, fueron obtenidos por identificación experimental<xref ref-type="bibr" rid="B40"><sup>40</sup></xref> y han sido los empleados para el diseño de algoritmos de control en los trabajos del Grupo de Automatización de Fuentes de Energía Renovables (AFER) de la Universidad de Oriente y en trabajos previos. <xref ref-type="bibr" rid="B6"><sup>6</sup></xref><sup>,</sup><xref ref-type="bibr" rid="B21"><sup>21</sup></xref><sup>,</sup><xref ref-type="bibr" rid="B38"><sup>38</sup></xref><sup>,</sup><xref ref-type="bibr" rid="B41"><sup>41</sup></xref><sup>,</sup><xref ref-type="bibr" rid="B42"><sup>42</sup></xref><sup>,</sup><xref ref-type="bibr" rid="B43"><sup>43</sup></xref>
			</p>
			<p>El modelo mostrado en la <xref ref-type="fig" rid="f5">figura 5</xref>, fue linealizado en entornos a un punto de operación correspondiente a la mitad de la potencia nominal y representado mediante funciones de transferencia. Como mecanismo actuador sobre el flujo de agua a la entada de la turbina, fue adaptado un servomotor que mueve la válvula de aguja de una turbina Pelton, en un rango limitado [Δl] con comportamiento integral (ver <xref ref-type="fig" rid="f4">figura 4</xref>). El mecanismo que actúa sobre la carga secundaria es un puente rectificador trifásico controlado que gobierna una carga resistiva (figura 4).</p>
			<p>
				<fig id="f5">
					<label>Fig. 5</label>
					<caption>
						<title>Diagrama de bloques del modelo de una micro-hidroeléctrica. </title>
					</caption>
					<graphic xlink:href="2224-6185-rtq-40-01-150-gf5.jpg"/>
					<attrib>Fuente (Domínguez, 1999)</attrib>
				</fig>
			</p>
			<p>Donde:</p>
			<p>
				<disp-formula id="e2">
					<label>(2)</label>
						<alternatives>
						<graphic xlink:href="2224-6185-rtq-40-01-150-i007.png"/>
					</alternatives>
					</disp-formula>
			</p>
			<p>Se conoce como el tiempo de inicio (arranque en algunas literaturas) del agua y se define como el tiempo necesario por una masa de agua a una altura determinada (H) y desde el reposo, para alcanzar la velocidad (V) a través de una longitud de tubería (L). El rango de variación típico de esta constante es ( 0.5 s≤𝑇 𝑎 ≤4 𝑠) a plena carga y cambia con el punto de operación.<sup>(20)</sup> Es usual, particularmente en las centrales cubanas, que el conducto forzado no sea de diámetro único, razón por la que en la expresión 2 se expresa como sumatoria de longitudes por las velocidades correspondientes. Es una constante muy importante en el diseño de centrales hidráulicas <xref ref-type="bibr" rid="B11"><sup>11</sup></xref> y para turbinas de reacción se toma en consideración además, el aporte a esta constante de la cámara espiral de las turbina.<xref ref-type="bibr" rid="B13"><sup>13</sup></xref>
			</p>
			<p>Un aspecto característico de las turbinas hidráulicas, desde el punto de vista de su comportamiento dinámico, es la existencia de un sistema de fase no mínima:<sup>(20)</sup> presencia de un cero en el semiplano derecho (ver <xref ref-type="fig" rid="f5">figura 5</xref>). Esta característica unida a las restricciones del tiempo de cierre de los elementos de admisión hace que el controlador deba ser adecuadamente diseñado para evitar el fenómeno del golpe de ariete y lograr estabilidad.Algunos procesos industriales presentan similar comportamientode respuesta inversa, como es el caso del control de nivel de calderas de vapor y la composición de fondo en columnas de destilación.</p>
			<p>Toda vez que el punto de operación de la turbina lo define el nivel de carga y el control por carga consiste en balancear, a través de una carga secundaria ( P 𝑙 ), el exceso o defecto de potencia requerido por los usuarios ( P 𝑢 ); el ajuste del punto de operación estará definido por la siguiente expresión: </p>
			<p>
				<disp-formula id="e3">
					<label>(3)</label>
						<alternatives>
						<graphic xlink:href="2224-6185-rtq-40-01-150-i011.png"/>
					</alternatives>
					</disp-formula>
			</p>
			<p>Y la decisión de ajuste del punto de operación en función de la potencia demandada cuando :</p>
			<p>
				<disp-formula id="e4">
						<alternatives>
						<graphic xlink:href="2224-6185-rtq-40-01-150-i012.png"/>
					</alternatives>
					</disp-formula>
			</p>
			<p>
				<disp-formula id="e5">
						<alternatives>
						<graphic xlink:href="2224-6185-rtq-40-01-150-i013.png"/>
					</alternatives>
					</disp-formula>
			</p>
			<p>En la <xref ref-type="fig" rid="f6">figura 6</xref>. Se muestra cómo varía el punto de operación de la turbina con la regulación automática combinada carga-flujo. En función del gasto a la entrada de la turbina varía su eficiencia ƞ (figura 6 curva a) y a su vez el gasto y la eficiencia definen el punto de operación que demanda la carga (figura 6 curva b) según la expresión (3). La potencia máxima alcanzable es de 100 kW como puede verse en la curva b, correspondiente a una carga hidráulica de 140 m y un gasto de 90 litros por segundo.</p>
			<p>
				<fig id="f6">
					<label>Fig. 6</label>
					<caption>
						<title>Variación del punto de operación con la regulación combinada. Curva característica de Eficiencia (a) y Potencia (b) versus Gasto. </title>
					</caption>
					<graphic xlink:href="2224-6185-rtq-40-01-150-gf6.png"/>
					<attrib>Fuente: (Autores, 2019)</attrib>
				</fig>
			</p>
		</sec>
		<sec sec-type="results|discussion">
			<title>Resultados y discusión del ajuste del esquema combinado carga-flujo</title>
			<p>Teniendo en cuenta que la dinámica del lazo de control por carga es menor que la del control por flujo ( 𝑇 2 ≫ 𝑇 𝑎 ), se pueden diseñar los dos lazos de control de forma independiente. Dado que el regulador por carga es más rápido toda vez que la constante de tiempo depende de elementos electrónicos y se desea obtener error cero a estado estacionario en el comportamiento de la frecuencia, se diseñará un regulador proporcional integral (PI). Para el caso del regulador por flujo, la presencia de un sistema de fase no mínima condiciona el empleo de una acción anticipatoria (acción derivativa), de igual forma, la acción integral está presente toda vez que la característica dinámica del elemento de acción sobre la válvula de admisión es de tipo integral como puede verse en la <xref ref-type="fig" rid="f5">figura 5</xref>. En la <xref ref-type="fig" rid="f7">figura 7</xref> se muestra el sistema de control combinado carga-flujo propuesto que permite el ajuste automático del punto de operación de la turbina.</p>
			<p>
				<fig id="f7">
					<label>Fig. 7</label>
					<caption>
						<title>Diagrama de bloques del sistema de control combinado. </title>
					</caption>
					<graphic xlink:href="2224-6185-rtq-40-01-150-gf7.jpg"/>
					<attrib>Fuente: (Autores, 2019)</attrib>
				</fig>
			</p>
			<p>Dadas la función de transferencia de un regulador PI definida por (4) y la función de transferencia a lazo abierto, del lazo por carga definida en (5).</p>
			<p>
				<disp-formula id="e6">
					<label>(4)</label>
						<alternatives>
						<graphic xlink:href="2224-6185-rtq-40-01-150-i017.png"/>
					</alternatives>
					</disp-formula>
			</p>
			<p>
				<disp-formula id="e7">
					<label>(5)</label>
						<alternatives>
						<graphic xlink:href="2224-6185-rtq-40-01-150-i018.png"/>
					</alternatives>
					</disp-formula>
			</p>
			<p>Empleando el método de asignación de polos, consistente en obtener los valores de la constante de acción proporcional K<sub>p</sub> y constante de tiempo de acción integral T<sub>i</sub></p>
			<p>tales que, los polos dominantes de la función de transferencia a lazo cerrado, de la frecuencia con respecto a una perturbación tipo escalón, produzca un comportamiento similar al de un polinomio de segundo orden como el representado en (5).</p>
			<p>
				<disp-formula id="e8">
					<label>(5)</label>
						<alternatives>
						<graphic xlink:href="2224-6185-rtq-40-01-150-i019.png"/>
					</alternatives>
					</disp-formula>
			</p>
			<p>Los polos <inline-graphic xlink:href="2224-6185-rtq-40-01-150-i020.png"/>están relacionados con el factor de amortiguamiento (𝜉), tiempo de establecimiento ( 𝑡 𝑠 ) y máximo sobrepaso ( 𝑚 𝑝 ) según las expresiones (6), (7), (8) y (9).</p>
			<p>
				<disp-formula id="e9">
					<label>(6)</label>
						<alternatives>
						<graphic xlink:href="2224-6185-rtq-40-01-150-i024.png"/>
					</alternatives>
					</disp-formula>
				</p>
				<p>
				<disp-formula id="e10">
					<label>(7)</label>
						<alternatives>
						<graphic xlink:href="2224-6185-rtq-40-01-150-i025.png"/>
					</alternatives>
					</disp-formula>
				</p>
				<p>
				<disp-formula id="e11">
					<label>(8)</label>
						<alternatives>
						<graphic xlink:href="2224-6185-rtq-40-01-150-i026.png"/>
					</alternatives>
					</disp-formula>
				</p>
				<p>
				<disp-formula id="e12">
					<label>(9)</label>
						<alternatives>
						<graphic xlink:href="2224-6185-rtq-40-01-150-i027.png"/>
					</alternatives>
					</disp-formula>
			</p>
			<p>Igualando el polinomio característico de la función de transferencia a lazo cerrado <inline-graphic xlink:href="2224-6185-rtq-40-01-150-i028.png"/>con el polinomio deseado representado por (5). Se obtienen los valores de las constantes de tiempo del regulador PI según (10) y (11).</p>
			<p>
				<disp-formula id="e13">
					<label>(10)</label>
						<alternatives>
						<graphic xlink:href="2224-6185-rtq-40-01-150-i029.png"/>
					</alternatives>
					</disp-formula>
			</p>
			<p>
				<disp-formula id="e14">
					<label>(11)</label>
						<alternatives>
						<graphic xlink:href="2224-6185-rtq-40-01-150-i030.png"/>
					</alternatives>
					</disp-formula>
			</p>
			<p>Mediante el procedimiento descrito para el regulador por carga, se diseña el regulador por flujo con función de transferencia 𝐺 𝑐𝑓 𝑠 y la función de transferencia por flujo a lazo abierto 𝐺 𝑝𝑓 (𝑠) definida en (13). La función de transferencia del actuador integral se considera convenientemente parte del regulador. En la práctica, este regulador proporcional derivativo (PD) se comporta como un PI al considerar la acción integral de la válvula. Para este caso el polinomio característico y por tanto el deseado, son de tercer orden.</p>
			<p>Al determinar la función de transferencia lazo cerrado<inline-graphic xlink:href="2224-6185-rtq-40-01-150-i033.png"/> e igualar ambos polinomios se obtienen las expresiones de 𝐾 𝑝 y 𝑇 𝑖 siguientes que definen los parámetros de ajuste del regulador por flujo:</p>
			<p>
				<disp-formula id="e15">
					<label>(12)</label>
						<alternatives>
						<graphic xlink:href="2224-6185-rtq-40-01-150-i036.png"/>
					</alternatives>
					</disp-formula>
			</p>
			<p>
				<disp-formula id="e16">
					<label>(13)</label>
						<alternatives>
						<graphic xlink:href="2224-6185-rtq-40-01-150-i037.png"/>
					</alternatives>
					</disp-formula>
			</p>
			<p>Fueron ajustados los dos lazos de control siguiendo el método de asignación de polos descrito en <xref ref-type="bibr" rid="B39"><sup>39</sup></xref> para los dos lazos por separado; de modo que el comportamiento deseado de la frecuencia cumpla con: Error a régimen estacionario dentro del rango de ± 1 Hz, tiempo de establecimiento menor de 60 s, máximo sobrepaso del error dentro del rango ± 1.5 Hz. En las figuras 8 y 9 se muestran el comportamiento de la frecuencia (a), demanda de carga (b), potencia secundaria (c) y desplazamiento del vástago de la válvula (d) respectivamente. La <xref ref-type="fig" rid="f8">figura 8</xref> muestra la respuesta de la planta antes perturbaciones de carga en el rango de la potencia secundaria. Sin embargo, la figura 8 muestra el comportamiento de la planta cuando las variaciones de carga son mayores que la carga secundaria. Las variaciones de carga se simularon según el diseño presentado en la <xref ref-type="table" rid="t1">tabla 1</xref>. (Ver <xref ref-type="fig" rid="f8">figuras 8</xref> (b) y <xref ref-type="fig" rid="f9">9 </xref>(b)). </p>
			<p>
				<table-wrap id="t1">
					<label>Tabla 1</label>
					<caption>
						<title>Tipo y magnitudes de perturbaciones simuladas. </title>
					</caption>
					<graphic xlink:href="2224-6185-rtq-40-01-150-gt1.jpg"/>
					<attrib>Fuente: (Autores, 2019)</attrib>
				</table-wrap>
			</p>
			<p>Como se aprecia, la frecuencia (figuras 8(a) y 9(a)) se comporta dentro de los valores deseados ante todas las perturbaciones simuladas, logrando alcanzar el valor deseado (60 Hz) en 25 segundos para el peor de los casos <xref ref-type="fig" rid="f9">(figura 9(a))</xref>. Cabe destacar que cuando las variaciones de la demanda están dentro del rango de variación de la carga secundaria <xref ref-type="fig" rid="f8">(figura 8)</xref>, la regulación combinada actúa de forma que, al compensar las perturbaciones, la regulación por flujo actúa haciendo que se vuelva al mismo punto de operación inicial (figura 7(d)). Sin embargo, cuando las perturbaciones son mayores que la carga secundaria, la diferencia de carga no compensada impone un ajuste del punto de operación según la expresión (3) a otro en función de la magnitud de la perturbación, tal como se muestra en la figura 9(d).</p>
			<p>
				<fig id="f8">
					<label>Fig. 8</label>
					<caption>
						<title>Respuesta de la planta con los métodos de regulación combinada ante perturbaciones de carga en el rango de la potencia secundaria.</title>
					</caption>
					<graphic xlink:href="2224-6185-rtq-40-01-150-gf8.jpg"/>
					<attrib> Fuente: (Autores, 2019)</attrib>
				</fig>
			</p>
			<p>
				<fig id="f9">
					<label>Fig. 9</label>
					<caption>
						<title>Respuesta la planta con los métodos de regulación combinada ante perturbaciones mayores que la potencia secundaria.</title>
					</caption>
					<graphic xlink:href="2224-6185-rtq-40-01-150-gf9.jpg"/>
					<attrib> Fuente: (Autores, 2019)</attrib>
				</fig>
			</p>
		</sec>
		<sec sec-type="conclusions">
			<title>Conclusiones</title>
			<p>Con la propuesta presentada en este trabajo, consistente en ajustar el punto de operación de las micro turbinas hidráulicas que trabajan de forma autónoma, se logra aumentar la calidad de la energía generada en las micro-centrales hidroeléctricas cubanas. De esta forma el aprovechamiento energético en estas centrales es mayor toda vez que se incentiva el consumo de energía, generando con determinados estándares de calidad referidos a las variaciones de la frecuencia generada. Con la combinación, como se aprecia en los resultados obtenidos, se aprovecha más eficientemente las ventajas de rapidez del control por carga y el seguimiento de la demanda del control por flujo, lo que garantiza un mejor aprovechamiento del portador energético. Los lazos de control fueron ajustados de forma que la respuesta dinámica de la frecuencia cumple con los requerimientos de diseño para redes aisladas e incluso para su eventual interconexión con otras mayores. Según los experimentos realizados, las variaciones de frecuencia permanecen dentro del rango permisible de ±0.5 Hz ante variaciones de carga impulsivas de hasta un 11% respecto a la potencia del generador y ±1,8 Hz del tipo escalón de hasta un 15.5 %. Los tiempos de establecimiento, en ambos casos son menores a los deseados, con 5 s ante cargas impulsivas de un 11% y 12 s para aumentos de carga sostenidos. En futuros trabajos los autores se plantean la sustitución de la carga resistiva por otras vías que aprovechen más eficientemente la energía generada.</p>
		</sec>
		<sec>
			<title>Nomenclatura</title>
			<p>P: Potencia [kW]</p>
			<p>Q: Gasto [m<sup>3</sup>/s]</p>
			<p>H: Carga hidráulica [m]</p>
			<p>f: Frecuencia de la tensión generada [Hz]</p>
			<p>Δl: Desplazamiento del vástago de la válvula de admisión de la turbina [mm]</p>
		</sec>
	</body>
	<back>
		<ack>
			<title>Agradecimientos</title>
			<p>Los autores de este trabajo agradecen la valiosa y desinteresada contribución del Profesor: PhD. Dorian Nedelcu, “EftimieMurgu” University of Reşiţa. Rumanía, en la construcción de la curva de rendimiento de la Turbina Pelton TP-15 mediante el software de su autoría <bold>HydroHillChart.</bold></p>
		</ack>
		<ref-list>
			<title>Referenciasbibliográficas</title>
			<ref id="B1">
				<label>1.</label>
				<mixed-citation>IRENA. &quot;Renewable energy technologies: cost analysis series&quot;. <ext-link ext-link-type="uri" xlink:href="www.irena.org: IRENA">www.irena.org: IRENA</ext-link>; 2012.</mixed-citation>
				<element-citation publication-type="book">
					<publisher-name>IRENA</publisher-name>
					<source>Renewable energy technologies: cost analysis series</source>
					<ext-link ext-link-type="uri" xlink:href="www.irena.org: IRENA">www.irena.org: IRENA</ext-link>
					<year>2012</year>
				</element-citation>
			</ref>
			<ref id="B2">
				<label>2</label>
				<mixed-citation>KUMAR V S, SINGAL S K. &quot;Operation of hydro power plants-a review&quot;, Renewable and Sustainable Energy Reviews, 2017, 69, (p.610-619),</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>KUMAR V</surname>
							<given-names>S</given-names>
						</name>
					</person-group>
					<person-group person-group-type="author">
						<name>
							<surname>SINGAL S</surname>
							<given-names>K.</given-names>
						</name>
					</person-group>
					<article-title>Operation of hydro power plants-a review</article-title>
					<source>Renewable and Sustainable Energy Reviews</source>
					<year>2017</year>
					<volume>69</volume>
					<fpage>610</fpage>
					<lpage>619</lpage>
				</element-citation>
			</ref>
			<ref id="B3">
				<label>3</label>
				<mixed-citation>WUBE D A. &quot;Design and Analysis of Small Hydro Power for Rural Electrification&quot;, Global Journal of Researchers in Engineering: F Electrical and Electronics Engineering, 2016,16 (6), ISSN:Online ISSN: 2249-4596 &amp; Print ISSN: 0975-5861</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>WUBE D</surname>
							<given-names>A.</given-names>
						</name>
					</person-group>
					<article-title>Design and Analysis of Small Hydro Power for Rural Electrification</article-title>
					<source>Global Journal of Researchers in Engineering: F Electrical and Electronics Engineering</source>
					<year>2016</year>
					<volume>16</volume>
					<issue>6</issue>
					<comment>2249-459</comment></element-citation>
			</ref>
			<ref id="B4">
				<label>4</label>
				<mixed-citation>SHARMA H, SINGH J. &quot;Run off River Plant: Status and Prospects&quot;, International Journal of Innovative Technology and Exploring Engineering (IJITEE), 2013, 3 (2), ISSN:ISSN: 2278-3075</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>SHARMA</surname>
							<given-names>H</given-names>
						</name>
					</person-group>
					<person-group person-group-type="author">
						<name>
							<surname>SINGH</surname>
							<given-names>J.</given-names>
						</name>
					</person-group>
					<article-title>Run off River Plant: Status and Prospects</article-title>
					<source>International Journal of Innovative Technology and Exploring Engineering (IJITEE)</source>
					<year>2013</year>
					<volume>3</volume><bold>(</bold><issue>2</issue>
					<issn>2278-3075</issn>
				</element-citation>
			</ref>
			<ref id="B5">
				<label>5</label>
				<mixed-citation>ASHFAQ H, SAOOD M, SINGH R. &quot;Autonomous micro-hydro power system for distributed generation: A power quality analysis&quot;, International Journal of Current Engineering and Scientific Research (IJCESR), 2015,2, (9), ISSN:ISSN (PRINT): 2393-8374, (ONLINE): 2394-0697</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>ASHFAQ</surname>
							<given-names>H</given-names>
						</name>
						<name>
							<surname>SAOOD</surname>
							<given-names>M</given-names>
						</name>
						<name>
							<surname>SINGH</surname>
							<given-names>R.</given-names>
						</name>
					</person-group>
					<article-title>Autonomous micro-hydro power system for distributed generation: A power quality analysis</article-title>
					<source>International Journal of Current Engineering and Scientific Research (IJCESR)</source>
					<year>2015</year>
					<volume>2</volume>
					<issue>9</issue>
					<issn>2393-8374</issn>
				</element-citation>
			</ref>
			<ref id="B6">
				<label>6</label>
				<mixed-citation>PEÑA P L, DOMÍNGUEZ A H, BARRIO J F, CHANG F. “Regulación de frecuencia por carga secundaria de una Minihidroeléctrica en régimen autónomo”. In: Feijoo, ed. XII Simposio de Ingeniería Eléctrica. Universidad Central Marta Abreu de Las Villas. 21-23 de junio del 2005. Cuba 2005.</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<name>
							<surname>PEÑA P</surname>
							<given-names>L</given-names>
						</name>
						<name>
							<surname>DOMÍNGUEZ A</surname>
							<given-names>H</given-names>
						</name>
						<name>
							<surname>BARRIO J</surname>
							<given-names>F</given-names>
						</name>
						<name>
							<surname>CHANG</surname>
							<given-names>F.</given-names>
						</name>
					</person-group>
					<source>Regulación de frecuencia por carga secundaria de una Minihidroeléctrica en régimen autónomo</source>
					<comment>In: Feijoo, ed. XII Simposio de Ingeniería Eléctrica</comment>
					<publisher-name>Universidad Central Marta Abreu de Las Villas</publisher-name>
					<publisher-loc>Cuba</publisher-loc>
					<year>2005</year>
				</element-citation>
			</ref>
			<ref id="B7">
				<label>7</label>
				<mixed-citation>HIDROENERGÍA. &quot;Estado de las Instalaciones actualizado 30-10-2018&quot;. Empresa de Hidroenegía: Unión Eléctrica; 2018.</mixed-citation>
				<element-citation publication-type="book">
					<source>Estado de las Instalaciones actualizado 30-10-2018</source>
					<publisher-name>Empresa de Hidroenegía: Unión Eléctrica</publisher-name>
					<year>2018</year>
				</element-citation>
			</ref>
			<ref id="B8">
				<label>8</label>
				<mixed-citation>NC62-04. &quot;Sistema Electroenergético Nacional. Frecuencia nominal y sus desviaciones permisibles&quot;. <ext-link ext-link-type="uri" xlink:href="http://www.nc.cubaindustria.cu">http://www.nc.cubaindustria.cu</ext-link>: Oficina Nacional de Normalización 1981:P. 3.</mixed-citation>
				<element-citation publication-type="book">
					<source>Sistema Electroenergético Nacional. Frecuencia nominal y sus desviaciones permisibles</source>
					<ext-link ext-link-type="uri" xlink:href="http://www.nc.cubaindustria.cu">http://www.nc.cubaindustria.cu</ext-link>
					<publisher-name>Oficina Nacional de Normalización</publisher-name>
					<year>1981</year>
				</element-citation>
			</ref>
			<ref id="B9">
				<label>9</label>
				<mixed-citation>NC800. Reglamento Electrotécnico Cubano para Instalaciones Eéctricas en Edificaciones NC 800:2017 (Ed. 2.0). <ext-link ext-link-type="uri" xlink:href="http://www.nc.cubaindustria.cu">http://www.nc.cubaindustria.cu</ext-link>: Oficina Nacional de Normalización 2017.</mixed-citation>
				<element-citation publication-type="book">
					<source>NC800. Reglamento Electrotécnico Cubano para Instalaciones Eéctricas en Edificaciones NC 800:2017 (Ed. 2.0)</source>
					<ext-link ext-link-type="uri" xlink:href="http://www.nc.cubaindustria.cu">http://www.nc.cubaindustria.cu</ext-link>
					<publisher-name>Oficina Nacional de Normalización</publisher-name>
					<year>2017</year>
				</element-citation>
			</ref>
			<ref id="B10">
				<label>10</label>
				<mixed-citation>HIDALGO G R. &quot;Estado de la Automática en las Hidroeléctricas de Cuba&quot;. In: Pupo L P, ed. Entrevista al Director de Desarrollo. Empresa de Hidroenergía. Dirección de Desarrollo 2018.</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<name>
							<surname>HIDALGO G</surname>
							<given-names>R.</given-names>
						</name>
					</person-group>
					<source>Estado de la Automática en las Hidroeléctricas de Cuba</source>
					<publisher-name>Empresa de Hidroenergía. Dirección de Desarrollo</publisher-name>
					<year>2018</year>
				</element-citation>
			</ref>
			<ref id="B11">
				<label>11</label>
				<mixed-citation>HRC. Small Hydropower. A Textbook Specially Designed for Trining Workshops in TCDC Program. 1ra ed: Zhejiang University Press 2006,</mixed-citation>
				<element-citation publication-type="book">
					<source>HRC. Small Hydropower. A Textbook Specially Designed for Trining Workshops in TCDC Program</source>
					<edition>1ra </edition>
					<publisher-name>Zhejiang University Press</publisher-name>
					<year>2006</year>
				</element-citation>
			</ref>
			<ref id="B12">
				<label>12</label>
				<mixed-citation>ESHA. &quot;Manual de Pequeña Hidraulica: Cómo llevar a buen fin un proyecto de minicentral hidroeléctrica&quot; 1998,</mixed-citation>
				<element-citation publication-type="book">
					<publisher-name>ESHA</publisher-name>
					<source>&quot;Manual de Pequeña Hidraulica: Cómo llevar a buen fin un proyecto de minicentral hidroeléctrica&quot;</source>
					<year>1998</year>
				</element-citation>
			</ref>
			<ref id="B13">
				<label>13</label>
				<mixed-citation>SOUZA Z D, MOREIRA S A H, DA COSTA B E. &quot;Centrais hidreléctricas: implantação e comissionamento&quot;. 3. ed. Rio de Janeiro 2018 2018,</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<name>
							<surname>SOUZA Z</surname>
							<given-names>D</given-names>
						</name>
						<name>
							<surname>MOREIRA S A</surname>
							<given-names>H</given-names>
						</name>
						<name>
							<surname>DA COSTA B</surname>
							<given-names>E</given-names>
						</name>
					</person-group>
					<source>Centrais hidreléctricas: implantação e comissionamento</source>
					<edition>3</edition>
					<publisher-loc>Rio de Janeiro</publisher-loc>
					<year>2018</year>
				</element-citation>
			</ref>
			<ref id="B14">
				<label>14</label>
				<mixed-citation>CEI. &quot;IEC 61362. Guía para la especificación de los sistemas de regulación de las turbinas Hidráulicas&quot;. Primera edición 1998-03. Asociación Española de Normalización y Certificación. AENOR 1998.</mixed-citation>
				<element-citation publication-type="book">
					<source>IEC 61362. Guía para la especificación de los sistemas de regulación de las turbinas Hidráulicas</source>
					<edition>Primera </edition>
					<month>03</month>
					<year>1998</year>
					<publisher-name>Asociación Española de Normalización y Certificación. AENOR</publisher-name>
				</element-citation>
			</ref>
			<ref id="B15">
				<label>15</label>
				<mixed-citation>NEDELCU, DORIAN. BOSTAN, ADELINA, PERIS-BENDU, FLORIN. HydroHillChart: Pelton module Software used to Calculate the Hill Chart of the Pelton Hydraulic Turbines. ANALELE UNIVERSITĂŢII. “EFTIMIE MURGU” REŞIŢA. ANUL XXII, NR. 1, 2015, ISSN 1453 - 7397.</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<name>
							<surname>NEDELCU</surname>
							<given-names>DORIAN</given-names>
						</name>
						<name>
							<surname>BOSTAN</surname>
							<given-names>ADELINA</given-names>
						</name>
						<name>
							<surname>PERIS-BENDU</surname>
							<given-names>FLORIN</given-names>
						</name>
					</person-group>
					<source>HydroHillChart: Pelton module Software used to Calculate the Hill Chart of the Pelton Hydraulic Turbines</source>
					<publisher-name>ANALELE UNIVERSITĂŢII</publisher-name>
					<year>2015</year>
					<comment>issn 1453 - 7397</comment>
				</element-citation>
			</ref>
			<ref id="B16">
				<label>16</label>
				<mixed-citation>GARCÍA F L G. &quot;Macro optimización del proyecto y la explotación de las pequeñas centrales hidroeléctricas de las regiones montañosas&quot;. Tesis presentada en opción al grado científico de Doctor en Ciencias Técnicas: Universidad de Oriente; 2005.</mixed-citation>
				<element-citation publication-type="thesis">
					<person-group person-group-type="author">
						<name>
							<surname>GARCÍA F L</surname>
							<given-names>G.</given-names>
						</name>
					</person-group>
					<source>Macro optimización del proyecto y la explotación de las pequeñas centrales hidroeléctricas de las regiones montañosas</source>
					<comment content-type="degree">Tesis presentada en opción al grado científico de Doctor en Ciencias Técnicas</comment>
					<publisher-name>Universidad de Oriente</publisher-name>
					<year>2005</year>
				</element-citation>
			</ref>
			<ref id="B17">
				<label>17</label>
				<mixed-citation>HIDROENERGÍA. &quot;Banco de Problemas de las Instalaciones Hidroeléctricas&quot;: Unión Eléctrica; 2018 Enero de 2018.</mixed-citation>
				<element-citation publication-type="book">
					<source>&quot;Banco de Problemas de las Instalaciones Hidroeléctricas&quot;</source>
					<publisher-name>Unión Eléctrica</publisher-name>
					<year>2018</year>
				</element-citation>
			</ref>
			<ref id="B18">
				<label>18</label>
				<mixed-citation>ILIEV V, PREDAG P, MARKOV Z. &quot;Transient Phenomena Analysis in Hydropower Plants at Off-Design Operating Conditions&quot;, International Journal of Engineering Research and Applications (IJERA), 2012,2 (6), p. 8, 1480-1488</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>ILIEV</surname>
							<given-names>V</given-names>
						</name>
						<name>
							<surname>PREDAG</surname>
							<given-names>P</given-names>
						</name>
						<name>
							<surname>MARKOV</surname>
							<given-names>Z.</given-names>
						</name>
					</person-group>
					<article-title>Transient Phenomena Analysis in Hydropower Plants at Off-Design Operating Conditions</article-title>
					<source>International Journal of Engineering Research and Applications (IJERA)</source>
					<year>2012</year>
					<volume>2</volume>
					<issue>6</issue>
					<fpage>8</fpage>
					<lpage>8</lpage>
				</element-citation>
			</ref>
			<ref id="B19">
				<label>19</label>
				<mixed-citation>DREIDY M, MOKHLIS H, MEKHILEF S. &quot;Inertia response and frequency control techniques for renewable energy sources: A review&quot;, Renewable and Sustainable Energy Reviews, 2017,69, (2017), p. 144-155,DOI:http://dx.doi.org/10.1016/j.rser.2016.11.170</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>DREIDY</surname>
							<given-names>M</given-names>
						</name>
						<name>
							<surname>MOKHLIS</surname>
							<given-names>H</given-names>
						</name>
						<name>
							<surname>MEKHILEF</surname>
							<given-names>S.</given-names>
						</name>
					</person-group>
					<article-title>Inertia response and frequency control techniques for renewable energy sources: A review</article-title>
					<source>Renewable and Sustainable Energy Reviews</source>
					<year>2017</year>
					<volume>69</volume>
					<year>2017</year>
					<fpage>144</fpage>
					<lpage>155</lpage>
					<pub-id pub-id-type="doi">http://dx.doi.org/10.1016/j.rser.2016.11.170</pub-id>
				</element-citation>
			</ref>
			<ref id="B20">
				<label>20</label>
				<mixed-citation>PRABHA K. &quot;Power System Stability and Control&quot;: McGraw-Hill Inc. 1994,</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<name>
							<surname>PRABHA</surname>
							<given-names>K.</given-names>
						</name>
					</person-group>
					<source>Power System Stability and Control</source>
					<publisher-name>McGraw-Hill Inc.</publisher-name>
					<year>1994</year>
				</element-citation>
			</ref>
			<ref id="B21">
				<label>21</label>
				<mixed-citation>DOMÍNGUEZ H, ARAFET P, CHANG F, PEÑA L, ALMAGUER H. &quot;Control combinado borroso de la frecuencia de una unidad minihidroeléctrica en operación autónoma&quot;. XIV Congreso Brasileiro de Automática Natal-RN. Brasil 2002.</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<name>
							<surname>DOMÍNGUEZ</surname>
							<given-names>H</given-names>
						</name>
						<name>
							<surname>ARAFET</surname>
							<given-names>P</given-names>
						</name>
						<name>
							<surname>CHANG</surname>
							<given-names>F</given-names>
						</name>
						<name>
							<surname>PEÑA</surname>
							<given-names>L</given-names>
						</name>
						<name>
							<surname>ALMAGUER</surname>
							<given-names>H.</given-names>
						</name>
					</person-group>
					<source>Control combinado borroso de la frecuencia de una unidad minihidroeléctrica en operación autónoma</source>
					<comment>XIV Congreso Brasileiro de Automática Natal-RN.</comment>
					<publisher-loc>Brasil</publisher-loc>
					<year>2002</year>
				</element-citation>
			</ref>
			<ref id="B22">
				<label>22</label>
				<mixed-citation>KUMAR R. &quot;Review and Analysis on Electronic Load Controller&quot;, International Journal of Engineering Sciences &amp; Management, 2017,January, 2017</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>KUMAR</surname>
							<given-names>R.</given-names>
						</name>
					</person-group>
					<article-title>Review and Analysis on Electronic Load Controller</article-title>
					<source>International Journal of Engineering Sciences &amp; Management</source>
					<month>06</month>
					<year>2017</year>
				</element-citation>
			</ref>
			<ref id="B23">
				<label>23</label>
				<mixed-citation>KHODADOOST A A A, KARAMI H, GHAREHPETIAN G B, HEJAZI M S A. &quot;Review of Flywheel Energy Storage Systems structures and applications in power systems and microgrids&quot;, Renewable and Sustainable Energy Reviews, 2017,69, (2017), p. 9-18,</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>KHODADOOST A A</surname>
							<given-names>A</given-names>
						</name>
						<name>
							<surname>KARAMI</surname>
							<given-names>H</given-names>
						</name>
						<name>
							<surname>GHAREHPETIAN G</surname>
							<given-names>B</given-names>
						</name>
						<name>
							<surname>HEJAZI M S</surname>
							<given-names>A.</given-names>
						</name>
					</person-group>
					<article-title>Review of Flywheel Energy Storage Systems structures and applications in power systems and microgrids</article-title>
					<source>Renewable and Sustainable Energy Reviews</source>
					<year>2017</year>
					<volume>69</volume>
					<fpage>9</fpage>
					<lpage>18</lpage>
				</element-citation>
			</ref>
			<ref id="B24">
				<label>24</label>
				<mixed-citation>DATTA A, BHATTACHARJEE K, DEBBARMA S, KAR B. &quot;Load Frequency Control of a Renewable Energy Sources based Hybrid System&quot;. In: IEEE, ed. 2015 IEEE Conference on Systems, Process and Control (ICSPC 2015). Bandar Sunway, Malaysia 2015.</mixed-citation>
				<element-citation publication-type="confproc">
					<person-group person-group-type="author">
						<name>
							<surname>DATTA</surname>
							<given-names>A</given-names>
						</name>
						<name>
							<surname>BHATTACHARJEE</surname>
							<given-names>K</given-names>
						</name>
						<name>
							<surname>DEBBARMA</surname>
							<given-names>S</given-names>
						</name>
						<name>
							<surname>KAR</surname>
							<given-names>B.</given-names>
						</name>
					</person-group>
					<source>Load Frequency Control of a Renewable Energy Sources based Hybrid System</source>
					<conf-name>Conference on Systems, Process and Control (ICSPC 2015)</conf-name>
					<conf-loc>Malaysia</conf-loc>
					<conf-date>2015</conf-date>
				</element-citation>
			</ref>
			<ref id="B25">
				<label>25</label>
				<mixed-citation>SEBASTIÁN R, QUESADA J. &quot;Modeling and simulation of an isolated wind Hydro Power System&quot;. In: IEEE, ed. IECON 2016 - 42nd Annual Conference of the IEEE Industrial Electronics Society. Florence, Italy 2016:p. 4169-4174.</mixed-citation>
				<element-citation publication-type="confproc">
					<person-group person-group-type="author">
						<name>
							<surname>SEBASTIÁN</surname>
							<given-names>R</given-names>
						</name>
						<name>
							<surname>QUESADA</surname>
							<given-names>J.</given-names>
						</name>
					</person-group>
					<source>Modeling and simulation of an isolated wind Hydro Power System</source>
					<conf-name>42ndAnnual Conference of the IEEE Industrial Electronics Society.</conf-name>
					<conf-loc>Florence, Italy </conf-loc>
					<conf-date>2016</conf-date>
				</element-citation>
			</ref>
			<ref id="B26">
				<label>26</label>
				<mixed-citation>MOHANRAJAN S R, VIJAYAKUMARI A, KOTTAYIL S K. &quot;Power Balancing in Autonomous Micro Grid with Variable Speed Pump&quot;. In: IEEE, ed. IEEE International Conference on Power, Control, Signals and Instrumentation Engineering (ICPCSI-2017) 2017.</mixed-citation>
				<element-citation publication-type="confproc">
					<person-group person-group-type="author">
						<name>
							<surname>MOHANRAJAN S</surname>
							<given-names>R</given-names>
						</name>
						<name>
							<surname>VIJAYAKUMARI</surname>
							<given-names>A</given-names>
						</name>
						<name>
							<surname>KOTTAYIL S</surname>
							<given-names>K.</given-names>
						</name>
					</person-group>
					<source>Power Balancing in Autonomous Micro Grid with Variable Speed Pump</source>
					<conf-name>International Conference on Power, Control, Signals and Instrumentation Engineering (ICPCSI-2017)</conf-name>
					<conf-date>2017</conf-date>
				</element-citation>
			</ref>
			<ref id="B27">
				<label>27</label>
				<mixed-citation>YUNIAHASTUTI T I, ANSHORI I, ROBANDI I. Load Frequency Control (LFC) of Micro-hydro Power Plant with Capacitive Energy Storage (CES) using Bat Algorithm (BA). 2016 International Seminar on Application for Technology of Information and Communication; 2016; 2016.</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<name>
							<surname>YUNIAHASTUTI T</surname>
							<given-names>I</given-names>
						</name>
						<name>
							<surname>ANSHORI</surname>
							<given-names>I</given-names>
						</name>
						<name>
							<surname>ROBANDI</surname>
							<given-names>I.</given-names>
						</name>
					</person-group>
					<source>Load Frequency Control (LFC) of Micro-hydro Power Plant with Capacitive Energy Storage (CES) using Bat Algorithm (BA)</source>
					<year>2016</year>
					<publisher-name>International Seminar on Application for Technology of Information and Communication</publisher-name>
					<year>2016</year>
				</element-citation>
			</ref>
			<ref id="B28">
				<label>28</label>
				<mixed-citation>SEBASTIÁN R, PEÑA A R. &quot;Simulation of an isolated Wind Diesel System with battery energy storage&quot;, Renewable and Sustainable Energy Reviews, 2011,81, (2011), p. 677-686,</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>SEBASTIÁN</surname>
							<given-names>R</given-names>
						</name>
						<name>
							<surname>PEÑA A</surname>
							<given-names>R.</given-names>
						</name>
					</person-group>
					<article-title>Simulation of an isolated Wind Diesel System with battery energy storage</article-title>
					<source>Renewable and Sustainable Energy Reviews</source>
					<year>2011</year>
					<volume>81</volume>
					<fpage>677</fpage>
					<lpage>686</lpage>
				</element-citation>
			</ref>
			<ref id="B29">
				<label>29</label>
				<mixed-citation>SEBASTIÁN R. &quot;Application of a battery energy storage for frequency regulation and peak shaving in a wind diesel power system&quot;, IET Generation, Transmission &amp; Distribution, 2016,10, (3), 764-770, ISSN:1751-8695</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>SEBASTIÁN</surname>
							<given-names>R.</given-names>
						</name>
					</person-group>
					<article-title>Application of a battery energy storage for frequency regulation and peak shaving in a wind diesel power system</article-title>
					<source>IET Generation, Transmission &amp; Distribution</source>
					<year>2016</year>
					<volume>10</volume>
					<issue>3</issue>
					<fpage>764</fpage>
					<lpage>770</lpage>
					<issn>1751-8695</issn>
				</element-citation>
			</ref>
			<ref id="B30">
				<label>30</label>
				<mixed-citation>GUO B, BACHA S, ALAMIR M, IMANEIN H. &quot;An anti-disturbance ADRC based MPTT for variable speed micro-hydropower station&quot;. In: IEEE, editor. IECON 2017 - 43rd Annual Conference of the IEEE Industrial Electronics Society; 2017 29 Oct.-1 Nov. 2017 Beijing, China IEEE; 2017. p. p. 1783-1789.</mixed-citation>
				<element-citation publication-type="confproc">
					<person-group person-group-type="author">
						<name>
							<surname>GUO</surname>
							<given-names>B</given-names>
						</name>
						<name>
							<surname>BACHA</surname>
							<given-names>S</given-names>
						</name>
						<name>
							<surname>ALAMIR</surname>
							<given-names>M</given-names>
						</name>
						<name>
							<surname>IMANEIN</surname>
							<given-names>H.</given-names>
						</name>
					</person-group>
					<source>An anti-disturbance ADRC based MPTT for variable speed micro-hydropower station</source>
					<conf-name>43rdAnnual Conference of the IEEE Industrial Electronics Society</conf-name>
					<conf-date>2017</conf-date>
					<conf-loc>Beijing, China </conf-loc>
				</element-citation>
			</ref>
			<ref id="B31">
				<label>31</label>
				<mixed-citation>BELHADJI L, BACHA S, ROYE D, REKIOUA T. Experimental Validation of Direct Power Control of Variable Speed Micro-Hydropower Plant. In: IEEE, ed. IECON 2012 - 38th Annual Conference on IEEE Industrial Electronics Society. 25-28 Oct. 2012, Montreal. 2012.</mixed-citation>
				<element-citation publication-type="confproc">
					<person-group person-group-type="author">
						<name>
							<surname>BELHADJI</surname>
							<given-names>L</given-names>
						</name>
						<name>
							<surname>BACHA</surname>
							<given-names>S</given-names>
						</name>
						<name>
							<surname>ROYE</surname>
							<given-names>D</given-names>
						</name>
						<name>
							<surname>REKIOUA</surname>
							<given-names>T.</given-names>
						</name>
					</person-group>
					<source>Experimental Validation of Direct Power Control of Variable Speed Micro-Hydropower Plant</source>
					<conf-name>38thAnnual Conference on IEEE Industrial Electronics Society</conf-name>
					<conf-loc>Montreal</conf-loc>
					<conf-date>2012</conf-date>
				</element-citation>
			</ref>
			<ref id="B32">
				<label>32</label>
				<mixed-citation>ALI W, FAROOQ H, REHMAN A U, FARRAG M E. Modeling and performance analysis of micro-hydro generation controls considering power system stability. 2017 First International Conference on Latest trends in Electrical Engineering and Computing Technologies (INTELLECT): IEEE 2017:p. 1-7.</mixed-citation>
				<element-citation publication-type="confproc">
					<person-group person-group-type="author">
						<name>
							<surname>ALI</surname>
							<given-names>W</given-names>
						</name>
						<name>
							<surname>FAROOQ</surname>
							<given-names>H</given-names>
						</name>
						<name>
							<surname>REHMAN A</surname>
							<given-names>U</given-names>
						</name>
						<name>
							<surname>FARRAG M</surname>
							<given-names>E.</given-names>
						</name>
					</person-group>
					<source>Modeling and performance analysis of micro-hydro generation controls considering power system stability</source>
					<conf-date>2017</conf-date>
					<conf-name>First International Conference on Latest trends in Electrical Engineering and Computing Technologies (INTELLECT)</conf-name>
				</element-citation>
			</ref>
			<ref id="B33">
				<label>33</label>
				<mixed-citation>DOOLLA A) S, BHATTI T S. &quot;Load Frequency Control of an Isolated Small-Hydro Power Plant With Reduced dump Load&quot;, IEEE Transaction on Power Systems, 2006,21 (4), 1912</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>DOOLLA A)</surname>
							<given-names>S</given-names>
						</name>
						<name>
							<surname>BHATTI T</surname>
							<given-names>S.</given-names>
						</name>
					</person-group>
					<article-title>Load Frequency Control of an Isolated Small-Hydro Power Plant With Reduced dump Load</article-title>
					<source>IEEE Transaction on Power Systems</source>
					<year>2006</year>
					<volume>21</volume>
					<issue>4</issue>
				</element-citation>
			</ref>
			<ref id="B34">
				<label>34</label>
				<mixed-citation>DOOLLA B) S, BHATTI T S. &quot;Automatic Frequency Control of an Isolated Small Hydro Power Plant&quot;, International Energy Journal, 2006,7 (1), p. 17-26,</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>DOOLLA B)</surname>
							<given-names>S</given-names>
						</name>
						<name>
							<surname>BHATTI T</surname>
							<given-names>S.</given-names>
						</name>
					</person-group>
					<article-title>Automatic Frequency Control of an Isolated Small Hydro Power Plant</article-title>
					<source>International Energy Journal</source>
					<year>2006</year>
					<volume>7</volume>
					<issue>1</issue>
					<fpage>17</fpage>
					<lpage>26</lpage>
				</element-citation>
			</ref>
			<ref id="B35">
				<label>35</label>
				<mixed-citation>VILAS K S, AKOLKAR S M. &quot;Load Frequency Control of Micro Hydro Power Plant using Fuzzy Logic Controller&quot;. In: IEEE, ed. IEEE International Conference on Power, Control, Signals and Instrumentation Engineering (ICPCSI-2017) 2017.</mixed-citation>
				<element-citation publication-type="confproc">
					<person-group person-group-type="author">
						<name>
							<surname>VILAS K</surname>
							<given-names>S</given-names>
						</name>
						<name>
							<surname>AKOLKAR S</surname>
							<given-names>M.</given-names>
						</name>
					</person-group>
					<source>Load Frequency Control of Micro Hydro Power Plant using Fuzzy Logic Controller</source>
					<conf-name>IEEE International Conference on Power, Control, Signals and Instrumentation Engineering (ICPCSI-2017)</conf-name>
					<conf-date>2017</conf-date>
				</element-citation>
			</ref>
			<ref id="B36">
				<label>36</label>
				<mixed-citation>BORY P H, MARTÍNEZ G H, VÁZQUEZ S L, CHANG M F, ENRÍQUEZ G L A. &quot;Comparison of Three-Phase Rectifier with Symmetrical Switching and AC-AC Converter for the Power Factor Improvement in Hydroelectric Micro-Plants&quot;, Revista Iberoamericana de Automática e Informática industrial 15 (2018) 101-111, 2018,15, (2018), 11, p. 101-111</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>BORY P</surname>
							<given-names>H</given-names>
						</name>
						<name>
							<surname>MARTÍNEZ G</surname>
							<given-names>H</given-names>
						</name>
						<name>
							<surname>VÁZQUEZ S</surname>
							<given-names>L</given-names>
						</name>
						<name>
							<surname>CHANG M</surname>
							<given-names>F</given-names>
						</name>
						<name>
							<surname>ENRÍQUEZ G L</surname>
							<given-names>A.</given-names>
						</name>
					</person-group>
					<article-title>Comparison of Three-Phase Rectifier with Symmetrical Switching and AC-AC Converter for the Power Factor Improvement in Hydroelectric Micro-Plants</article-title>
					<source>Revista Iberoamericana de Automática e Informática industrial</source>
					<volume>15</volume>
					<year>2018</year>
					<fpage>101</fpage>
					<lpage>111</lpage><bold>15</bold></element-citation>
			</ref>
			<ref id="B37">
				<label>37</label>
				<mixed-citation>YADAV R K, MATHEW L. &quot;Load Frequency control of an Isolated Small Hydro Power Plant with Reduction in Dump Load Rating By Using Variable Structure Control&quot;, International Journal of Engineering Science Invention, 2014,3 (5), 8-15, 8, ISSN:2319-6734</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>YADAV R</surname>
							<given-names>K</given-names>
						</name>
						<name>
							<surname>MATHEW</surname>
							<given-names>L.</given-names>
						</name>
					</person-group>
					<article-title>Load Frequency control of an Isolated Small Hydro Power Plant with Reduction in Dump Load Rating By Using Variable Structure Control</article-title>
					<source>International Journal of Engineering Science Invention</source>
					<year>2014</year>
					<volume>3</volume>
					<issue>5</issue>
					<fpage>8</fpage>
					<lpage>15</lpage>
					<issn>2319-6734</issn>
				</element-citation>
			</ref>
			<ref id="B38">
				<label>38</label>
				<mixed-citation>PEÑA P L, FONG B J, DOMÍNGUEZ A H, CHANG M F, GARCÍA-ALZORRIZ P J A, TOLEDANO I M. “Regulación de frecuencia de una Minihidroeléctrica por carga secundaria utilizando un PC embebido de uso industrial”. . In: Oriente U d, ed. Conferencia Científica Internacional ELECTRICA’ 2004 Universidad de Oriente. Santiago de Cuba. 14-16 de julio del 2004. ISBN 959-11-0452-9. 2004.</mixed-citation>
				<element-citation publication-type="confproc">
					<person-group person-group-type="author">
						<name>
							<surname>PEÑA P</surname>
							<given-names>L</given-names>
						</name>
						<name>
							<surname>FONG B</surname>
							<given-names>J</given-names>
						</name>
						<name>
							<surname>DOMÍNGUEZ A</surname>
							<given-names>H</given-names>
						</name>
						<name>
							<surname>CHANG M</surname>
							<given-names>F</given-names>
						</name>
						<name>
							<surname>GARCÍA-ALZORRIZ P J</surname>
							<given-names>A</given-names>
						</name>
						<name>
							<surname>TOLEDANO I</surname>
							<given-names>M.</given-names>
						</name>
					</person-group>
					<source>Regulación de frecuencia de una Minihidroeléctrica por carga secundaria utilizando un PC embebido de uso industrial</source>
					<conf-name>Conferencia Científica Internacional ELECTRICA’</conf-name>
					<conf-date>2004</conf-date>
					<conf-loc>Santiago de Cuba</conf-loc>
				</element-citation>
			</ref>
			<ref id="B39">
				<label>39</label>
				<mixed-citation>PEÑA P L, DOMINGUEZ A H, FONG B J, GARCIA-ALZÓRRIS P J A. &quot;Regulación de frecuencia en una Minihidrolectrica por carga lastre mediante un pc Embebido&quot;. 9th Spanish Potuguese Congress on Electrical Engineering (9CHLIE); 2005; Marbella, España. 30/6 -2/7 de 2005: Book of Summaries. pp 151-152.; 2005. p. p. 151-152.</mixed-citation>
				<element-citation publication-type="confproc">
					<person-group person-group-type="author">
						<name>
							<surname>PEÑA P</surname>
							<given-names>L</given-names>
						</name>
						<name>
							<surname>DOMINGUEZ A</surname>
							<given-names>H</given-names>
						</name>
						<name>
							<surname>FONG B</surname>
							<given-names>J</given-names>
						</name>
						<name>
							<surname>GARCIA-ALZÓRRIS P J</surname>
							<given-names>A.</given-names>
						</name>
					</person-group>
					<source>Regulación de frecuencia en una Minihidrolectrica por carga lastre mediante un pc Embebido</source>
					<conf-name>9thSpanish Potuguese Congress on Electrical Engineering (9CHLIE)</conf-name>
					<conf-loc>Marbella, España</conf-loc>
				</element-citation>
			</ref>
			<ref id="B40">
				<label>40</label>
				<mixed-citation>DOMÍNGUEZ A H. &quot;Modelado y simulación para el análisis y diseño de algoritmos de control de una pequeña unidad hidroeléctrica&quot;.Tesis presentada en opción al título de Máster en Control Automático: Universidad de Oriente.; 1999.</mixed-citation>
				<element-citation publication-type="thesis">
					<person-group person-group-type="author">
						<name>
							<surname>DOMÍNGUEZ A</surname>
							<given-names>H.</given-names>
						</name>
					</person-group>
					<source>Modelado y simulación para el análisis y diseño de algoritmos de control de una pequeña unidad hidroeléctrica</source>
					<comment content-type="degree">Tesis presentada en opción al título de Máster en Control Automático</comment>
					<publisher-name>Universidad de Oriente</publisher-name>
					<year>1999</year>
				</element-citation>
			</ref>
			<ref id="B41">
				<label>41</label>
				<mixed-citation>DOMÍNGUEZ H, ARAFET P, CHANG F, PEÑA L. &quot;Fuzzy Switched Mode Control for a Linearized Plant subjected to impulsive load disturbances&quot;. XI Congreso Latinoamericano de Control Automático; 2004 10-15 de mayo del 2004; Ciudad de la Habana. Cuba: Instituto Superior Politécnico José Antonio Echevarría. CUJAE; 2004.</mixed-citation>
				<element-citation publication-type="confproc">
					<person-group person-group-type="author">
						<name>
							<surname>DOMÍNGUEZ</surname>
							<given-names>H</given-names>
						</name>
						<name>
							<surname>ARAFET</surname>
							<given-names>P</given-names>
						</name>
						<name>
							<surname>CHANG</surname>
							<given-names>F</given-names>
						</name>
						<name>
							<surname>PEÑA</surname>
							<given-names>L.</given-names>
						</name>
					</person-group>
					<source>Fuzzy Switched Mode Control for a Linearized Plant subjected to impulsive load disturbances</source>
					<conf-name>XICongreso Latinoamericano de Control Automático</conf-name>
					<conf-date>2004 10-15 de mayo</conf-date>
					<conf-loc>Ciudad de la Habana, Cuba</conf-loc>
				</element-citation>
			</ref>
			<ref id="B42">
				<label>42</label>
				<mixed-citation>DOMÍNGUEZ H, FONG B J. &quot;Control Robusto de la frecuencia de una pequeña unidad hidroeléctrica en operación aislada&quot;, Revista Energía y Computación, 2003, 11(1), p. 11-18,</mixed-citation>
				<element-citation publication-type="journal">
					<person-group person-group-type="author">
						<name>
							<surname>DOMÍNGUEZ</surname>
							<given-names>H</given-names>
						</name>
						<name>
							<surname>FONG B</surname>
							<given-names>J.</given-names>
						</name>
					</person-group>
					<article-title>Control Robusto de la frecuencia de una pequeña unidad hidroeléctrica en operación aislada</article-title>
					<source>Revista Energía y Computación</source>
					<year>2003</year>
					<volume>11</volume>
					<issue>1</issue>
					<fpage>11</fpage>
					<lpage>18</lpage>
				</element-citation>
			</ref>
			<ref id="B43">
				<label>43</label>
				<mixed-citation>PEÑA P L, DOMINGUEZ H, FONG J, GARCIA-ALZÓRRIS P J A. &quot;Regulación de frecuencia en una Minihidrolectrica por carga lastre mediante un pc Embebido&quot;. 9th Spanish Potuguese Congress on Electrical Engineering (9CHLIE); 2005; Marbella, España. 30/6 -2/7 de 2005: Book of Summaries. pp 151-152.; 2005. p. p. 151-152.</mixed-citation>
				<element-citation publication-type="book">
					<person-group person-group-type="author">
						<name>
							<surname>PEÑA P</surname>
							<given-names>L</given-names>
						</name>
						<name>
							<surname>DOMINGUEZ</surname>
							<given-names>H</given-names>
						</name>
						<name>
							<surname>FONG</surname>
							<given-names>J</given-names>
						</name>
						<name>
							<surname>GARCIA-ALZÓRRIS P J</surname>
							<given-names>A.</given-names>
						</name>
					</person-group>
					<source>Regulación de frecuencia en una Minihidrolectrica por carga lastre mediante un pc Embebido</source>
					<edition>9th </edition>
					<publisher-name>Spanish Potuguese Congress on Electrical Engineering (9CHLIE)</publisher-name>
					<publisher-loc>Marbella, España</publisher-loc>
					<fpage>151</fpage>
					<lpage>152</lpage>
				</element-citation>
			</ref>
		</ref-list>
	</back>
</article>